Firmware
3.0.24
June 20, 2018 View All Updates

Recommendation

Update all MXA910 devices in a configuration to the same firmware version.

Improvements

  • DSP Updates
    • Faster Auto Position performance: Only 2-3 seconds required for auto position setup
    • Echo Reduction Meter and Faders: Enhanced echo reference level control
    • EQ Contour: New presets for faster room tuning
    • Send to Mix: Assign selected channels to direct out only or direct out and Automix
    • Pre- and Post-Automix Fader
    • Pre- and Post-Automix Mute
    • Automix Gain Meters
  • Hardware Light Bar
    • More color options (now 17 total)
    • More brightness levels (now 6 total, including off)
  • New command strings
  • Bug fixes
    • Devices lock up due to TPCI connection issues
    • Users access GUI without completing password recovery

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported.

Notes

  • User Guide
  • Command strings
  • MXA910 version 3.0.24 is compatible with MXA910 devices running version 3.0.24 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA910 version 3.0.24 with Dante™ Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA910 version 3.0.24 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 2.0.19
    • Designer 3.0
    • MXA310 3.0.24
    • Microflex Wireless 5.2.2
    • P300 IntelliMix® Audio Conferencing Processor 2.1.6
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.2
    • Shure Web Device Discovery 1.2
Firmware
3.0.24
June 20, 2018 View All Updates

Recommendation

Update all MXA310 devices in a configuration to the same firmware version.

Improvements

  • DSP
    • Per-Channel PEQ: Adds PEQ to all channels in MXA310
    • Send to Mix: Assign selected channels to direct out only or direct out and Automix
    • Pre- and Post-Automix Fader
    • Pre- and Post-Automix Mute
    • Automix Gain Meters
  • Hardware Light Ring
    • More color options (now 17 total)
    • More brightness levels (now 6 total, including off)
  • New command strings
  • Bug fixes
    • Devices lock up due to TPCI connection issues
    • Users access GUI without completing password recovery

Known Issues

  • After updating from version 2.X to 3.0.24, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

Notes

  • User Guide
  • Command strings
  • MXA310 version 3.0.24 is compatible with MXA310 devices running version 3.0.24 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.0.24 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.0.24 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 2.0.19
    • MXA910 3.0.24
    • Microflex Wireless 5.2.2
    • P300 IntelliMix® Audio Conferencing Processor 2.1.6
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.2
    • Shure Web Device Discovery 1.2
Firmware
3.0.24
June 20, 2018 View All Updates

Recommendation

Update all MXA310 devices in a configuration to the same firmware version.

Improvements

  • DSP
    • Per-Channel PEQ: Adds PEQ to all channels in MXA310
    • Send to Mix: Assign selected channels to direct out only or direct out and Automix
    • Pre- and Post-Automix Fader
    • Pre- and Post-Automix Mute
    • Automix Gain Meters
  • Hardware Light Ring
    • More color options (now 17 total)
    • More brightness levels (now 6 total, including off)
  • New command strings
  • Bug fixes
    • Devices lock up due to TPCI connection issues
    • Users access GUI without completing password recovery

Known Issues

  • After updating from version 2.X to 3.0.24, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

Notes

  • User Guide
  • Command strings
  • MXA310 version 3.0.24 is compatible with MXA310 devices running version 3.0.24 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.0.24 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.0.24 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 2.0.19
    • MXA910 3.0.24
    • Microflex Wireless 5.2.2
    • P300 IntelliMix® Audio Conferencing Processor 2.1.6
    • ULXD4D/4Q 2.2.24
    • SCM820 1.3.3
    • Shure Update Utility 2.4.2
    • Shure Web Device Discovery 1.2
Firmware
1.0.29
June 18, 2018 View All Updates

Important

  • This version applies to AD1 and AD2 transmitters

Improvement

  • Resolves intermittent issue in which frequency on transmitter could reset to default value (Group 1, Channel 1) when batteries are fully drained.

Notes

  • AD1/2 version 1.0.29 is compatible with AD1/2 devices on version 1.0.29 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate AD1/2 version 1.0.29 devices with other Shure systems and software, see the following list of minimum versions:
    • Axient Digital AD4D/Q Receivers 1.0.27
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4
    • Wireless Workbench 6.12.2
Firmware
2.2.24
June 14, 2018 View All Updates

Important

  • Before ULX-D and QLX-D receivers can host or update ULXD6/8 firmware, they must be updated to the following minimum firmware versions:
    • ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
    • QLXD4 Receivers 2.1.5 or higher
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all ULX-D devices to the same version.

Improvements

  • Support for new frequency bands
    • Latin America 632 – 696 MHz (L50)
    • Taiwan: 510-530 MHz (G62)
    • U.S. 572 – 616 MHz (J50A)
    • U.S. 653 – 663 MHz (L50A)
  • Bug fixes

Known Issue

  • ULXD6/8 transmitters are not compatible with SystemOn 2.0-3.0.1

Notes

  • ULXD6/8 User Guide
  • To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
    1. Update receivers to the following minimum versions:
      • ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
      • QLXD4 Receivers 2.1.5 or higher
    2. Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
    3. Using the FW Update menu on a receiver, update transmitters.
  • To update ULXD6/8 transmitters firmware while they are docked in an SBC250/450/850 Networked Charging Station:
    1. Place transmitters on charging station and ensure charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate ULXD6/8 version 2.2.24 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.2.24
    • SBC250/450/850 Networked Charging Stations 2.2.24
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
    • Wireless Workbench 6.12.4
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4.1
Firmware
2.2.24
June 14, 2018 View All Updates

Important

  • Before ULX-D and QLX-D receivers can host or update ULXD6/8 firmware, they must be updated to the following minimum firmware versions:
    • ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
    • QLXD4 Receivers 2.1.5 or higher
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all ULX-D devices to the same version.

Improvements

  • Support for new frequency bands
    • Latin America 632 – 696 MHz (L50)
    • Taiwan: 510-530 MHz (G62)
    • U.S. 572 – 616 MHz (J50A)
    • U.S. 653 – 663 MHz (L50A)
  • Bug fixes

Known Issue

  • ULXD6/8 transmitters are not compatible with SystemOn 2.0-3.0.1

Notes

  • ULXD6/8 User Guide
  • To update firmware for ULXD6/8 transmitters with ULX-D or QLX-D receivers:
    1. Update receivers to the following minimum versions:
      • ULXD4, ULXD4D, and ULXD4Q Receivers 2.1.16 or higher
      • QLXD4 Receivers 2.1.5 or higher
    2. Using Shure Update Utility, download ULXD6/8 transmitter firmware to the receivers.
    3. Using the FW Update menu on a receiver, update transmitters.
  • To update ULXD6/8 transmitters firmware while they are docked in an SBC250/450/850 Networked Charging Station:
    1. Place transmitters on charging station and ensure charging station is connected to the network.
    2. Launch Shure Update Utility to find firmware updates.
    3. Download updates and select Send Updates.
  • To operate ULXD6/8 version 2.2.24 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.2.24
    • SBC250/450/850 Networked Charging Stations 2.2.24
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
    • Wireless Workbench 6.12.4
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4.1
Firmware
2.2.24
June 14, 2018 View All Updates

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

New Feature

  • AES67 support

Improvements

  • Support for new frequency bands:
    • U.S. 572 – 616 MHz (J50A)
    • U.S. 653 – 663 MHz (L50A)
  • Bug fixes, including fixing the issue of ULXD1/2 transmitters on version 2.2.23 getting reset to factory default settings after an update or downgrade.

Known Issue

  • ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 2.0-3.0.1

Notes

  • User Guide
  • If your ULXD1/2 transmitter is on version 2.2.23, updating to version 2.2.24 will unexpectedly reset your ULXD1 to its factory default settings and your previous settings will need to be recovered via IR sync.
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • SystemOn 3.0.1 displays "Check system requirements, your current firmware version may not be confirmed compatible" for ULX-D version 2.2.24; however only ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 3.0.1.
  • To operate ULX-D version 2.2.24 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD4/4D/4Q Receivers 2.2.24
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
    • Axient AXT600 Spectrum Manager 2.1.11
    • Wireless Workbench  6.12.4
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4.1
    • SystemOn 3.0.1
Firmware
2.2.24
June 14, 2018 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

New Feature

  • AES67 support

Improvements

  • Support for new frequency bands:
    • U.S. 572 – 616 MHz (J50A)
    • U.S. 653 – 663 MHz (L50A)
  • Bug fixes, including fixing the issue of ULXD1/2 transmitters on version 2.2.23 getting reset to factory default settings after an update or downgrade.

Known Issue

  • ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 2.0-3.0.1

Notes

  • User Guide
  • If your ULXD1/2 transmitter is on version 2.2.23, updating to version 2.2.24 will unexpectedly reset your ULXD1 to its factory default settings and your previous settings will need to be recovered via IR sync.
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • SystemOn 3.0.1 displays "Check system requirements, your current firmware version may not be confirmed compatible" for ULX-D version 2.2.24; however only ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 3.0.1.
  • To operate ULX-D version 2.2.24 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD4/4D/4Q Receivers 2.2.24
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
    • Axient AXT600 Spectrum Manager 2.1.11
    • Wireless Workbench  6.12.4
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4.1
    • SystemOn 3.0.1
Firmware
2.2.24
June 14, 2018 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

New Feature

  • AES67 support

Improvements

  • Support for new frequency bands:
    • U.S. 572 – 616 MHz (J50A)
    • U.S. 653 – 663 MHz (L50A)
  • Bug fixes, including fixing the issue of ULXD1/2 transmitters on version 2.2.23 getting reset to factory default settings after an update or downgrade.

Known Issue

  • ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 2.0-3.0.1

Notes

  • User Guide
  • If your ULXD1/2 transmitter is on version 2.2.23, updating to version 2.2.24 will unexpectedly reset your ULXD1 to its factory default settings and your previous settings will need to be recovered via IR sync.
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • SystemOn 3.0.1 displays "Check system requirements, your current firmware version may not be confirmed compatible" for ULX-D version 2.2.24; however only ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 3.0.1.
  • To operate ULX-D version 2.2.24 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD4/4D/4Q Receivers 2.2.24
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
    • Axient AXT600 Spectrum Manager 2.1.11
    • Wireless Workbench  6.12.4
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4.1
    • SystemOn 3.0.1
Firmware
2.2.24
June 14, 2018 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

New Feature

  • AES67 support

Improvements

  • Support for new frequency bands:
    • U.S. 572 – 616 MHz (J50A)
    • U.S. 653 – 663 MHz (L50A)
  • Added power supply fail-safe protection
  • Bug fixes

Known Issue

  • ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 2.0-3.0.1

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • SystemOn 3.0.1 displays "Check system requirements, your current firmware version may not be confirmed compatible" for ULX-D version 2.2.24; however only ULX-D devices on J50A or L50A frequency bands are not compatible with SystemOn 3.0.1.
  • To operate ULX-D version 2.2.24 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.2.24
    • SBC250/450/850 Networked Charging Stations 2.2.24
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.2.11
    • PSM1000 1.5.12
    • Axient AXT600 Spectrum Manager 2.1.11
    • Wireless Workbench 6.12.4
    • Shure Update Utility 2.4.2
    • ShurePlus Channels 1.4.1