Software
6.13.0
14/07/2019 View All Updates

New Features

Advanced Zone Management: An enhancement to the Zones feature the allows users be more deliberate about zone relationships, which can be configured to respect channel-to-channel or channel-to-intermodulation spacing.

  • Consider using zones when you need more frequencies than the Wireless Workbench calculator is able to find and when you are working with a venue that contains multiple separate spaces.
  • Zones change the way Wireless Workbench calculates and analyzes frequencies and should not be used purely for the organizational purposes. To keep frequenices organized, use Tags.

Online TV Channel Database Search (U.S. only): Added support for online searches of TV stations through an FCC-approved database provided by KeyBridge Global.

Improvements

  • Added support for macOS Mojave (10.14)

New Device and Frequency Band Support

  • New frequency band V52 for ULX-D.
  • New frequency band V52 for QLX-D.
  • New frequency band X55 for PSM1000.
  • New frequency band X55 for PSM900.
  • Added support for new frequency band M18 for SVX.
  • Added support for new frequency band H11 for BLX.
  • Added support for PGX-D frequency bands X8, X8A, and X8B.
  • Added support for Audix AP41 and AP61 systems.

Stability

  • WWB no longer crashes when attempting to delete the last available view tab in Timeline.
  • WWB no longer crashes when enabling Timeline or Mini-Timeline for some ULX-D devices
  • WWB no longer crashes sometimes while updating Custom Equipment Profiles that are currently in the Inventory.
  • WWB no longer freezes after saving a Timeline in one scenario.
  • WWB no longer freezes after attempting to resize the Coordination Chooser dialog in one scenario.
  • WWB no longer crashes after selecting a different network interface card (NIC) and quickly returning to an active Timeline.

Performance

  • Improved the reponse of the condensed meters in the Monitor view.
  • Improved the speed at which Channel Strips are displayed when added to Monitor views in large quantities.
  • Improved the speed at which the application preferences dialog opens.
  • Improved the speed at which the Inventory Report and Firmware and Network Summary Report are generated.
  • Improved the speed of frequency calculation and analysis in cases where 3T3O intermodulation products are not considered.
  • Improved Timeline data writing and plotting performance.

Networking

  • Made improvements to the network interface selection process during application launch that caused the display of devices from an incorrect network.

Inventory

  • Changes to an AD4Q frequency in the Inventory tab no longer affect its other channels.
  • There are no longer duplicate channels listed in the Inventory Group/Channel dropdown for ULXD6 and ULXD8 transmitters.
  • Frequency values in the Inventory are now displayed reliably for Custom Equipment Profiles.
  • Sorting the Inventory table by Device ID no longer incorrectly considers brackets [] as characters in the Device ID.
  • Improved the context menu for inventory rows by re-organizing the items.

Frequency Coordination

  • Updated the offline TV data for the following countries:
    • Austria
    • Finland
    • United States
  • Updated the Germany User Groups
  • Updated the layout of the Exclusions dialog to improve the ease of creating and viewing single frequency and frequency range exclusions.
  • Added "dBm" level to the Assign and Deploy dialog.
  • Removed "Pause" and "Resume" controls and consolidated into "Stop Calculation" in the Coordination Workspace.
  • Adjusting the Exclusion Threshold no longer creates duplicate frequency exclusions when re-calculating.
  • Searching in the TV Channels Database no longer rejects geographic coordinates that include a space after the comma separator.
  • Data sent to an AXT600 Spectrum Manager from WWB no longer causes a conflict when their TV Formats are different.

Monitoring

  • Added a confirmation dialog when closing Monitor views to prevent accidental closure.
  • The Properties Panel for AD4 receivers now shows Mic/Line and Ground/Lift status for redundant outputs when the device is in FD-C or Quadversity Mode.
  • The Properties Panel for AD4Q no longer shows the wrong Dante Channel Name while in Quadversity Mode.
  • The Properties Panel for QLXD now correctly shows the Transmitter Mute alert in its Channel Strip when used with ULXD1 and ULXD2 transmitters.
  • The values for certain properties of SBC220 and SBC240 are now remembered in their Properties Panel when ganged devices go offline.
  • Properties Pnael for SBC240 now allows access to Device Settings when the maximum number of ganged units has been exceeded.
  • Alert text is now removed from certain charger Properties Panels when the alert is no longer active.
  • Low Battery Bar alerts are now cleared from the Hardware Alerts dialog after disabling them in Preferences in one scenario.
  • Dragging and dropping channel rows from the Device Chooser in the Monitor tab now creates Mini-Timelines in addition to Channel Strips.
  • Added RF Power as a comppnent of Channl Strip widgets.

Timeline

  • Added support for Timeline file recovery in the vent that WWB or Timeline unexpectedly quits.
  • Saved Timeline files now include the tab naame and date/time in the default filename.
  • Added Battery Charge Percentage as an option in the Timeline Battery Data Stream.
  • Added a Timeline System Event for battery errors.
  • Transmitter Device ID in the Channel Strip Receiver/Transmitter Controls section now stays updated when another transmitter overwrites it while it is offline.
  • ShowLink data is now shown on the correct Transmitter Slot in Mini-Timeline when the view is changed to an empty Slot, the widget is hidden, and then shown again.
  • Searching for Timeline User Markers using the search bar now considers text in the Marker Descriptions field.
  • Opening Timeline no longer creates a 0 byte file by default when opened.

General

  • Added application preference for temperature units (Celsius or Fahrenheit)
  • Added ability to enable/disable Access Control from the Device Settings in a Properties Panel.
  • Added MAC Address field to the Firmware and Network Summary Report.
  • Resizing dialogs on Mac is no longer disabled.
  • Dropdowns on Mac are no longer oversized or undersized.
  • Certain IR Presets on AXT400 no longer favor WWB automatically when the Conflict Settings dialog is ignored.
  • Renamed "Flash" actions to "Identify," but still trigger networked devices to blink their displays and LEDs.
  • 600 MHz Conversion Utility no longer fails to convert transmitters on MacOS in one scenario.
  • Channel Strips now retain the selected Receiver/Transmitter Controls page in saved Show Files.

Known Issues

  • ULX-D receivers running firmware version 2.0.28 or earlier may trigger a Settings Conflict when rediscovered after updating their firmware to version 2.1 or later. There is no issue with the device – there was simply a new property added in version 2.1. To dismiss the alert, resolve the Settings Conflict by selecting the properties you wish to keep.
  • Certain bodypack portables are not compatible with SBC220 (P3RA, P9HW, and UR5), in that the charging status and other attributes cannot be remotely monitored from WWB. These bodypack portables will still be charged when using SBC220, but viewing the charge percentage or other attributes of those batteries will not be available from WWB.
  • Audio Summing reported from ULX-D receivers reports an Audio Overload on all channels instead of on the specific channel(s) experiencing the overload.
  • Timeline System Events displayed when using the Axient Digital FD-Override (in FD-S, selecting to Lock to Rx 1/2/Auto Switch) do not get displayed on both FD channels.
  • Alerts logged when devices first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
  • SLX and ULX frequencies in Master List mode cannot be manually entered in the Coordination Workspace. They can, however, be coordinated and analyzed.
  • On Windows, certain components of a channel strip may be hidden from view when the computer's display scaling is not set to the default value. As a workaround: close the application, right-click on the application executable, select the Compatibility tab, select the Override high DPI scaling behavior checkbox, and choose System (Enhanced) in the Scaling performed by dropdown. This will prevent the application display from scaling higher or lower, but it will ensure that the Channel Strip is entirely visible.

Notes

  • To operate Wireless Workbench successfully, you must run it as an administrator. (Consult your IT department if you have questions.)
  • Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench."
Software
6.8.29
27/06/2019 View All Updates

Important

  • This version is used to upgrade from all previous SW6000 versions, however it cannot be used to upgrade systems using CU 6005, CU 6010 or CU 6011 Central Units
  • This version is compatible with SW6000 Software License file v1.7 only
  • No new SW6000 license is needed if upgrading from SW6000 v6.0.xxx or later versions
  • A new SW6000 license is needed if upgrading from SW6000 v5.8.xxx or previous versions

New Features

CUI

  • Run as Admin restriction removed

CAA

  • The Meeting role agenda settings are now included in one pop-up window. The setting includes the following new options:
    • View icons for pre-request-to speak, voting result, hyperlink and subject status
    • View Pre-request-to-speak list in agenda
    • Pre-request-to speak control and view options
  • The Meeting/Options window now includes Agenda options
  • Multiple simultaneous web service connections is now supported
  • Assigning participants to a pre-request-to-speak list per subject in agenda
  • Run as Admin restriction removed

CUA

  • Option to set participants proxy relations in the Participant screen
  • Run as Admin restriction removed
  • CUA appearance settings moved from ‘prjCUA.exe.config’ file to skin file in sub-folder ‘Resources’
  • Auto-showing of voting result, short description and description in the agenda if present in the subject
  • Agenda view in ‘full’ screen by covering pane if pane is not active
  • Agenda view improvement by use of skin file in sub-folder ‘Resources’. The following is configurable:
    • Font/color/size for each agenda level
    • Include short description for any subject and not only in level 1
    • Include description for any subject
    • Include agenda time for any subject
    • Number of max. lines for agenda levels, short description and description
    • Lines between subjects (show/not show, color and thickness)
    • Distance between subjects
    • Icons for pre-request-to speak, voting result, hyperlink and subject status
    • Margins
    • Include list of pre-request-to speak for any subject with sorting options in up to 3 columns. The sorting option uses the ‘Sort order’ defined in the ‘Group table’
  • ‘Pre-request’ list pane in the Agenda screen:
    • Shows the list of pre-request-to-speak for the selected subject
    • Participants options:
      • Pre-request to speak
      • View own request with status
      • View all approved requests
      • Remove own request
    • Control options (Meeting role based) to:
      • Add a participant
      • Approve
      • Reject
      • Remove
      • Change the order in the list

CDA

  • Run as Admin restriction removed
  • Interpretation system status:
    • Booth channel list for technician
    • Channel list for public
    • Booth channel language for individual booth

Known Issue

  • Full support for the C-language is not implemented in the CAA and CUA

Notes

Firmware
3.1.6
27/06/2019 View All Updates

Recommendation

Update all Audio Network Interfaces in a configuration to the newest firmware versions.

Improvement

  • Fix for web server performance issues

Known Issues

  • After updating from version 2.X to 3.1.6, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.6 is compatible with MXA310 devices running version 3.1.6 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.6 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.6
    • ULXD4D/4Q 2.3.34
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
Firmware
3.1.6
27/06/2019 View All Updates

Recommendation

Update all Audio Network Interfaces in a configuration to the newest firmware versions.

Improvement

  • Fix for web server performance issues

Known Issues

  • After updating from version 2.X to 3.1.6, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > ResponseActual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC >LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL >LOGIC
< REP MUTE_BUTTON OFF >DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.6 is compatible with MXA310 devices running version 3.1.6 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.6 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.6
    • ULXD4D/4Q 2.3.34
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
Firmware
3.1.6
27/06/2019 View All Updates

Recommendation

Update all Audio Network Interfaces in a configuration to the newest firmware versions.

Improvement

  • Fix for web server performance issues

Known Issues

  • There is the potential for a loss of audio after a power cycle when using Static IP setting: Un-checking and re-checking the Dante connections is necessary to reestablish audio between devices. An Alternative fix is to use DHCP addressing.
  • TCPI set 0 for input level switch also incorrectly changes the output level switch and vice versa.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).

Notes

  • User Guide
  • Command Strings
  • ANIUSB-MATRIX version 3.1.6 is compatible with ANIUSB-MATRIX devices running version 3.1.6 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate ANIUSB-MATRIX version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate ANIUSB-MATRIX version 3.1.6 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • P300 3.1.6
    • ULXD4D/4Q 2.3.34
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
Software
3.2
12/06/2019 View All Updates

Improvements

  • Support for MXA910 firmware version 4.0.12 with IntelliMix® DSP
  • Bug fixes

Known Issues

  • Discovering MXW microphones may take more than 1 minute
  • If a single location has more than 32 devices, the audio metering quality will decrease
  • UTC time and date are displayed on Event Log and Email/SMS notifications.
  • Navigating through an Event Log with hundreds of events may be slow or could cause the system to time out.
  • For non-English users setting up SMS notifications, the Senders Phone Number field does not show the required (*), but the field is required.
  • If a valid license activation ID is applied and fails on the first attempt, please try again before calling support.

Notes

  • To operate SystemOn 3.2 with Shure networked systems, see the following list of supported firmware versions:
    • SCM820 1.3.3
    • ULX-D 2.2.24 – 2.3.34
    • MXW 5.2.2 – 6.0.3
    • MXA910 3.15 – 4.0.12
    • MXA310 3.1.5
    • P300 3.1.6
    • ANIUSB-MATRIX 3.1.5
    • SBC220/240 1.1.43 – 1.1.62
    • SBC250/450/850 2.2.24 – 2.3.6
  • Please report SystemOn performance issues experienced on supported browsers to Shure Support.
  • For help and troubleshooting, go to the SystemOn User Guide or FAQs
Software
3.2.0
12/06/2019 View All Updates
*****
UPDATE: Oct 15, 2019: Designer 3.2 supports P300 devices updated to version 3.1.8.
*****

 

IMPORTANT
  • When upgrading Designer versions, the installer will prompt that the destination folder C:\Program Files\Shure\Shure\Shure Designer is not empty; please change the Shure Designer folder name (e.g. Shure Designer 3.1) or delete the existing Shure Designer folder and it will automatically be re-created during the upgrade.
  • In order to push from virtual devices to online devices, or vice versa, the virtual device and online version must be of the same version. For example, all new virtual MXA910s created in Designer 3.2 are on version 4.0.12; those virtual devices can only be associated with online devices that are also on firmware version 4.0.12.

 

IMPROVEMENTS
  • Support for MXA910 firmware version 4.0.12 with IntelliMix® DSP
  • Bug fixes

 

KNOWN ISSUES
  • When using MXA910 4.0.12 firmware, the Sync Status between the virtual and online device will appear as ‘Not Synced.’
  • If no NIC is selected, some features on virtual devices may not work as expected, e.g. deleting lobes from virtual MXA910s; select a NIC to fix the issue.
  • When using Windows 7, no more than five windows can be open simultaneously.
  • Templates that were created from a location will be empty when the project is exported and then imported. This does not affect locations that were not copied to templates.
  • With more than 20 devices in location or 60 on the network, some actions will take longer due to increased network traffic.
  • When pushing to many devices, the status may incorrectly show that the push failed. For most devices, if the Sync Status changes from ‘Not Synced’ to ‘Synced’, then the push was successful. However, with MXA910 version 4.0.12, the status will always say ‘Not Synced.’
  • When deleting a virtual device, Designer will warn that encryption and password settings will be changed; however, the discovered devices’ encryption and password settings will not be affected.
  • When working with virtual devices and presets, channel names do not revert to default values when “Restore Default Settings” is clicked, and location may take time to respond.
  • In Coverage Map, changing the unit of measurement will not be saved for the location; the unit of measurement will default to feet when the location is reopened.                                          When importing a Designer preset file into the MXA910 web application, attempts to immediately export that file out of the web application will fail if it is not first loaded and saved to the MXA910.
  • When changing an exported project file name and attempting to import the project file, an error message may appear although the project was successfully imported; switch tabs or close and re-open the app to view the project.

 

NOTES
  • Internet access is required during the installation process
  • Designer User Guide
  • System Requirements
  • Designer 3.2 is compatible with the following firmware versions:
    • MXA310 version 3.1.5
    • MXA910 version 4.0.12
    • P300 version 3.1.6
    • ANIUSB-MATRIX version 3.1.5
  • Requires 64-bit Windows 7, 8.1 or 10
Firmware
3.1.6
12/06/2019 View All Updates

Improvements

  • Support for logic functionality with MXA910 version 4.0.12 firmware

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.6 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.5
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
Firmware
4.0.12
12/06/2019 View All Updates

Recommendation

Update all MXA910 devices in a configuration to the same firmware version. Devices on version 4.0.12 cannot be downgraded to previous versions.

Improvements

  • Incorporates IntelliMix® DSP including AEC, Noise Reduction, Automatic mixing, AGC, Compressor, Delay and EQ. IntelliMix® uses Shure’s patent-pending acoustic echo cancellation technology to deliver a single channel of auto-mixed, noise- and echo-free audio.
  • Patent-pending Autofocus™ technology continually fine-tunes the position of each lobe in real time, for consistent sound when participants lean back in their chairs, or even stand up.

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.0 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • To operate MXA910 version 4.0.12 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA910 version 4.0.12 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • MXA310 3.1.5
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.6
    • ULXD4D/4Q 2.3.21
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
App
1.1.3
28/05/2019 View All Updates

IMPROVEMENTS

  • Bug fixes

 

KNOWN ISSUES

  • Some users of iPhone 8 or iPhone X may experience silence or noisy artifacts on their recordings. iOS 11.3 includes a fix for this issue, so we strongly suggest that all users with either of these phones upgrade to the latest version of iOS.
  • If the screen is locked while a MOTIV microphone is plugged in, the app may no longer be able to access it. To fix this issue, return to the home screen, force-close the app, then unplug and re-plug the microphone.
  • Users of iPhone 8 who are running iOS 11.3 may experience crashes when playing back saved recordings from within the app.
  • If you monitor your recordings with Bluetooth earphones, you may hear artifacts, such as noise, while monitoring. If this occurs, we recommend changing the sample rate of your recordings. Some products may produce artifacts at 44.1 kHz, while others may do so for 48 kHz recordings. Please keep in mind that even if you hear artifacts while monitoring, they will not be present in the recordings themselves.

 

NOTES