Downloads
Software & Firmware Archives
Firmware
2.0.27
November 29, 2017
Visualizza Tutti Gli Aggiornamenti
New Feature
- Access Control: When activated, Access Control enables users to specify a PIN from Wireless Workbench (version 6.12.4.1 and higher) to protect the device from being changed by unauthenticated users of Wireless Workbench.
Improvements
- Bug fixes
Notes
- User Guide
- To operate Axient 2.0.27 devices with other Shure systems and software, see the following list of minimum versions:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULX-D ULXD4X Receivers 2.1.16
- QLX-D QLXD4 Receiver 2.1.5
- PSM1000 P10T Transmitter 1.4.2
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
2.0.27
November 29, 2017
Visualizza Tutti Gli Aggiornamenti
New Feature
- Support for Axient Digital
Improvements
- Support for new frequency bands:
- Support for discovery over the network of the following frequency bands:
- Bug fixes
*AXT600 is capable of discovering ULX-D and QLX-D receivers in X52, X53, X54, V50, V51, Z16, Z19 and Z20 bands. AXT600 will continue to scan within the range of 470-865, 925-952 MHz. In the AXT600 band summary list, any band that is not fully supported due to non-tunable frequencies is tagged with *. In the AXT600 CFL list, non-tunable frequencies are indicated with "Monitor for WWB (unknown dBm)". When listening to CFL frequencies, switching to a non-tunable frequency will turn the Listen mode off. The AXT600 CFL Edit/Add menu will allow any frequency for any band, not limited to tunable frequencies.
Notes
- User Guide
- To operate Axient 2.0.27 devices with other Shure systems and software, see the following list of minimum versions:
Firmware
2.0.27
November 29, 2017
Visualizza Tutti Gli Aggiornamenti
Improvements
- Bug fixes
Known Issue
- When an AXT400 J is set to one of the newly supported UHF-R bands (e.g. G1HK, H4HK, J5HK, L3HK), downgrading the AXT400 J unit from 1.17.10 to 1.15.3 may result in abnormal frequency indication (e.g. 0.000 MHz) as well as a change in the RF band.
Notes
- To operate Axient 2.0.27 devices with other Shure systems and software, see the following list of minimum versions:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULX-D ULXD4X Receivers 2.1.16
- QLX-D QLXD4 Receiver 2.1.5
- PSM1000 P10T Transmitter 1.4.2
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
2.0.27
November 29, 2017
Visualizza Tutti Gli Aggiornamenti
Improvements
- Bug fixes
Notes
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- To operate Axient 2.0.27 devices with other Shure systems and software, see the following list of minimum versions:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULX-D ULXD4X Receivers 2.1.16
- QLX-D QLXD4 Receiver 2.1.5
- PSM1000 P10T Transmitter 1.4.2
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
2.0.27
November 29, 2017
Visualizza Tutti Gli Aggiornamenti
Improvements
- Bug fixes
Notes
- Transmitters to be used with receivers must be updated via IR. After the receiver is updated, go to the receiver menu: Tx > IRPresets > FWUpdate. Align the infrared ports with the transmitter and press Download.
- To operate Axient 2.0.27 devices with other Shure systems and software, see the following list of minimum versions:
- UR4 UHF-R receiver 1.171
- UR3 Plug-on Transmitter 1.0.0.16
- UR5 Portable Diversity Receiver 1.0.0.13
- ULX-D ULXD4X Receivers 2.1.16
- QLX-D QLXD4 Receiver 2.1.5
- PSM1000 P10T Transmitter 1.4.2
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
8.2.2
November 23, 2017
Visualizza Tutti Gli Aggiornamenti
Important
- This firmware release can be used to upgrade units in a DDS 5900 or a DCS 6000 systems using CU 5905, CU 6105, CU 6110 or DIS CCU Central Units.
- The CU 6000, CU 6005, CU 6010 and CU 6011 Central Units are not supported in this release.
- The DIS FUU Firmware Upgrade Utility, which is part of this firmware release, must be used when upgrading
New Features
- CU/CUU: Added multi-language support for WEB-UI and Name Sign.
- CU 5905/CCU(5900 mode) - Support for TPCI mic_attenuation command
Improvements
- CU/CCU - Ensures channel selectors get language abbreviation on/off setting repeatedly.
- SW6000, CU – Fixed the clearing request list so that the individual request Off comes before Clear Request List
- CU/CCU - Fixed CU response with Mic on, when sending microphone on message to an Interpreter that is not connected to the CU
- CU/CCU - CU is no longer resetting if interpreter settings are reset while the interpreter microphone is active
- CU/CCU - WEB-UI "View Open Source Licenses" now shows open source licenses instead of a "404 Not Found" html page
- CS6340F - After CU starts up, channel OLED on CS6340F now correctly shows channel language abbreviation instead of channel number
- IS6132 – There is no longer an audible difference in sound level on CU audio output, when comparing floor sound and interpreted audio
- SW6000, Interpreter, CU61xx, - Interpreter status is now correctly marked as "Lost" if unregistered rather than "Not Lost" and leading to wrong status in SW6000
- DC59xx – Fixed the "All delegate off" LED so that it is not ON when the button is pressed on DC59xx chairman units
- CU/CCU – In operation mode FIFO, the request list is now restored to speak list when selecting "All del off" on the WEB-UI
Notes
Firmware
1.0.21
November 20, 2017
Visualizza Tutti Gli Aggiornamenti
Important
- This version applies to AD1 and AD2 transmitters
Improvements
- Adds support for transmitter SKUs sold in Brazil
- Improved user interface
Notes
- AD1/2 version 1.0.21 is compatible with AD1/2 devices on version 1.0.21 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate AD1/2 version 1.0.21 devices with other Shure systems and software, see the following list of minimum versions:
- Axient Digital AD1/2 Transmitters 1.0.21
- Axient Digital AD4D/Q Receivers 1.0.21
- Axient AXT600 Spectrum Manager 2.0.27
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
2.1.6
November 20, 2017
Visualizza Tutti Gli Aggiornamenti
New Feature
- Initial firmware for the P300 IntelliMix Audio Conferencing Processor
Notes
- To operate P300-IMX version 2.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
- To operate P300-IMX version 2.1.6 with other Shure networked systems, reference the following list of minimum versions supported:
- ANI22 2.0.11
- ANIUSB-MATRIX 2.0.11
- ANI4IN 2.0.7
- ANI4OUT 2.0.8
- MXA310 2.0.7
- MXA910 2.0.16
- Microflex Wireless 5.1.23
- Shure Update Utility 2.4.1
- Shure Web Device Discovery 1.1
Firmware
1.0.21
November 20, 2017
Visualizza Tutti Gli Aggiornamenti
Improvements
- Support for transmitter SKUs sold in Brazil
- Support for DC modules
Notes
- AD4Q version 1.0.21 is compatible with AD4Q devices on version 1.0.21 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate AD4Q version 1.0.21 devices with other Shure systems and software, see the following list of minimum versions:
- Axient Digital AD1/2 Transmitters 1.0.21
- Axient Digital AD4D Receivers 1.0.21
- Axient AXT600 Spectrum Manager 2.0.27
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2
Firmware
1.0.21
November 20, 2017
Visualizza Tutti Gli Aggiornamenti
Improvements
- Support for transmitter SKUs sold in Brazil
- Support for DC modules
Notes
- AD4D version 1.0.21 is compatible with AD4D devices on version 1.0.21 and below, but it is recommended to update all devices used together to the same firmware version.
- To operate AD4D version 1.0.21 devices with other Shure systems and software, see the following list of minimum versions:
- Axient Digital AD1/2 Transmitters 1.0.21
- Axient Digital AD4Q Receivers 1.0.21
- Axient AXT600 Spectrum Manager 2.0.27
- SBRC Shure Battery Rack Charger 1.0.1
- Shure Update Utility 2.4.1
- ShurePlus Channels 1.4
- Wireless Workbench 6.12.2