Downloads

Software & Firmware Archives

Filter by update type

Type

Release Title

Latest Version

Associated Products

Download

Firmware
1.8.8
02/04/2012 View All Updates

NEW FEATURES

  • Support for the following Axient transmitter frequency Bands: MA24, G1E, H4E, J5E, MJBX, K4E, L3E, M8, P8, P9, Q5
  • Axient transmitters now support custom groups.
  • Axient and UHF-R transmitters can get Custom Groups from the AXT400 receiver via IR Sync (from AXT400 menu select Tx>IR Presets>CG, select ‘Sync Custom Groups’ and then IR Sync the transmitter).

NOTES

  • Transmitters to be used with receivers must be updated via IR. After updating the receiver, select Tx>IR Presets>FW Update from the receiver menu and align the infrared ports with the transmitter before selecting ‘Download’.
  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
    • UR4 UHF-R receiver - 1.166
    • UR3 Plug-on Transmitter - 1.0.0.9
    • UR5 Portable Diversity Receiver - 1.0.0.13
    • ULXD4 ULXD Receiver - 1.0.3
    • P10T PSM1000 Transmitter - 1.3.4
    • Wireless Workbench - 6.3.1 Beta
Firmware
1.8.8
02/04/2012 View All Updates

NEW FEATURES

  • Support for the following Axient transmitter frequency Bands: MA24, G1E, H4E, J5E, MJBX, K4E, L3E, M8, P8, P9, Q5
  • Support for the following Axient receiver variants: AXT400B, AXT400C
  • AXT400C receiver also supports the following UHF-R transmitter bands: A24, JBX, Q10a, Q5HK
  • The AXT400 receiver supports user-created frequency groups. Creation, editing and deployment of these groups to other receivers can be done from the front panel interface of the receiver (Radio>Options>Custom)
  • Custom Groups can also be created and edited from the AXT400 Properties panel in Wireless Workbench 6.
  • A Custom Group can include any frequency in the tunable range of the receiver. The selectable Channels within a Custom Group are filtered by the currently selected Band.
  • The Load function exports Custom Groups from a receiver over the network to other receivers of the same Model. This makes the Custom Groups available on the client receivers but does not set frequencies.
  • The Group Scan function can send Custom Groups to client Axient receivers set to the same band as the deploying receiver, and programs the client receivers with frequencies using the scan results.
  • Axient and UHF-R transmitters can get Custom Groups from the AXT400 receiver via IR Sync (from AXT400 menu select Tx>IR Presets>CG, select ‘Sync Custom Groups’ and then IR Sync the transmitter).

IMPROVEMENTS

  • Improved Front Panel Lock feature, allows some menu navigation to view settings while not allowing changes to parameters.
  • Improved resistance to interference from ultrasonic sources such as motion sensors.

KNOWN ISSUES

  • Using the AXT400 receiver as a scanning device from WWB6, the error message may appear: ‘Scanner reported no Scan ID Available’. This is triggered by a previous IR Sync operation from that receiver which included Custom Groups. The following actions will release the receiver from this state:
    • Start a scan from the receiver front panel menu (Radio>Scan, either Channel Scan or Group Scan function will clear the problem). It is not necessary to deploy the results of the scan.
    • Power cycle the receiver.

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
    • UR4 UHF-R receiver - 1.166
    • UR3 Plug-on Transmitter - 1.0.0.9
    • UR5 Portable Diversity Receiver - 1.0.0.13
    • ULXD4 ULX-D Receiver - 1.0.3
    • P10T PSM1000 Transmitter - 1.3.4
    • Wireless Workbench - 6.3.1 Beta
Firmware
1.8.8
02/04/2012 View All Updates

NEW FEATURES

  • Support for the following Axient receiver variants: AXT400B, AXT400C

IMPROVEMENTS

  • Improved Front Panel Lock feature, allows some menu navigation to view settings while not allowing changes to parameters.

KNOWN ISSUES

  • The old P10T firmware for production (v1.1.0) is not interoperable with the minimum Beta version (v1.3.1) that supports the networked features of Spectrum Manager and Wireless Workbench 6. When using the Axient Spectrum Manager and/or Wireless Workbench 6 with PSM1000, all P10T transmitter units to be used in the same network configuration must be updated to version 1.3.4 (which is available to download from within Wireless Workbench 6). Use the Firmware Update Manager Tool in Wireless Workbench 6 to update P10T transmitters and enable network discovery and programming with Wireless Workbench 6 and Spectrum Manager.

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
    • UR4 UHF-R receiver - 1.166
    • UR3 Plug-on Transmitter - 1.0.0.9
    • UR5 Portable Diversity Receiver - 1.0.0.13
    • ULXD4 ULXD Receiver - 1.0.3
    • P10T PSM1000 Transmitter - 1.3.4 Beta
    • Wireless Workbench - 6.3.0 Beta
Firmware
1.8.8
02/04/2012 View All Updates

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
    • UR4 UHF-R receiver - 1.166
    • UR3 Plug-on Transmitter - 1.0.0.9
    • UR5 Portable Diversity Receiver - 1.0.0.13
    • ULXD4 ULXD Receiver - 1.0.3
    • P10T PSM1000 Transmitter - 1.3.4 Beta
    • Wireless Workbench - 6.3.0 Beta
Firmware
1.8.8
02/04/2012 View All Updates

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
    • UR4 UHF-R receiver - 1.166
    • UR3 Plug-on Transmitter - 1.0.0.9
    • UR5 Portable Diversity Receiver - 1.0.0.13
    • ULXD4 ULXD Receiver - 1.0.3
    • P10T PSM1000 Transmitter - 1.3.4 Beta
    • Wireless Workbench - 6.3.0 Beta
Firmware
1.8.8
02/04/2012 View All Updates

NOTES

  • For operation of Axient devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with Axient version 1.8.8:
    • UR4 UHF-R receiver - 1.166
    • UR3 Plug-on Transmitter - 1.0.0.9
    • UR5 Portable Diversity Receiver - 1.0.0.13
    • ULXD4 ULXD Receiver - 1.0.3
    • P10T PSM1000 Transmitter - 1.3.4 Beta
    • Wireless Workbench - 6.3.0 Beta
Firmware
1.3.4
03/04/2012 View All Updates

Improvements

  • Added support for X2 band for use in Korea

Notes

  • For operation of PSM1000 devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with PSM1000 version 1.3.4:
    • Axient devices 1.8.8
    • ULX-D devices 1.0.3
    • Wireless Workbench 6 Beta version 6.3.0
Firmware
1.3.2
03/04/2012 View All Updates

IMPROVEMENTS

  • Improved IR sync protocol
  • Added support for X2 band

NOTES

  • For operation of PSM1000 devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with PSM1000 version 1.3.2:
    • Axient devices 1.9.2
    • ULX-D devices 1.0.7
    • Wireless Workbench 6 Beta version 6.4.0
Firmware
1.0.7
25/04/2012 View All Updates

Improvements

  • Fixed an IR Syncing issue with certain screen brightness settings

Known Issues

  • Custom group creation from Wireless Workbench may be limited to certain channel counts for the following bands (NOTE: not an issue when editing custom groups from the front panel of the receiver)
    • AB
    • JA
    • JB
    • Q51
    • R51
    • X50

Notes

  • For operation of ULX-D devices with other Shure networked systems, see the following list of minimum firmware versions that are supported with ULX-D version 1.0.7:
    • ULXD1/2 ULXD Transmitters 1.0.3
    • ULXD4 ULX-D Receivers 1.0.7
    • Wireless Workbench 6 Beta version 6.2.1
Software
5.6.28
19/05/2012 View All Updates

New Features

  • Showing of voting cast in secret voting implemented in CAA, CDA, CUA mimic and in voting reports
  • CAA "Agenda subject configuration" added
  • Secondary speech timer when main timer is paused
  • ‘One speech/Subject’
  • Request time limit
  • New CUA resolutions min 1280 x 800
  • Changed CUA resolution, min 1920x1200 changed to min 1920x1080
  • “Request List Closed” shown if the request list is closed manually
  • Reset request time function
  • Win Installation log can be viewed after installation
  • CUI improvements when handling STF
  • SW versions added in CUI log files
  • Warning when user is trying to overwrite backup file

Bug Fix

  • Voting report (Individual) corrected (results and labels)
  • DC 6990P configured as dual units cannot logout
  • CDA speech time error in Groups and 'header' font type
  • Voting graph configuration: Not possible to set CDA/CUA voting width
  • CDA remaining voting time are drifting away from CUA
  • Chairman in not identified as chairman, when Secondary seat is used
  • Improvements when using replacing mic. function in CAA setup equipment, conference units menu
  • Error in CDA Mimic, when showing interpreter language, corrected