Downloads

Software & Firmware Archives

Filter by update type

Type

Release Title

Latest Version

Associated Products

Baixe

Software
6.15.2
24/10/2022 View All Updates

New Device Support

  • Added support for the new AD600 Axient® Digital Spectrum Manager
    • Updated and increased scan speed time
    • Newly designed Property Panel for AD600
    • Multi-antenna configuration
    • Ability to import Custom User Groups from AD600

Improvements

  • The following issues were addressed in this update:
  • Scans and Plots
    • Wireless Workbench was unable to save a scan when a device ID contained special characters.
    • After relaunching Wireless Workbench, a crash would intermittently happen after previously selecting all the devices to start scanning and then trying to stop the scan.
    • The “Scan Storage Limit Reached” dialog was not correctly displayed when a scan would be greater than the storage limit available.
    • Importing scan data from ADX5D showed the same color for all antennas.
    • Wireless Workbench would crash by loading a CWS file while a live scan is in progress.
  • Device Management
    • .csv and .txt files were failing to import to Custom Groups.
    • Wireless Workbench would crash when a virtual AD4Q is dragged onto an online AD4Q for merging.
    • Wireless Workbench might crash when closing the “select from frequency list dialog” when a spectrum manager is online.
    • Custom Groups are now shareable with PSM1000 and other IEM devices.
  • Monitoring
    • ADX5D would display power source, battery sled model, and serial number as blank after switching between wired power supply and battery sled.

Known Issues

  • Wireless Workbench is limiting a continuous scan to 8 hours.
  • Battery type may not persist between power cycles for SLX-D transmitters on firmware version 1.0.13. To resolve, you must set the battery type on the transmitter again.
  • ULX-D receivers running firmware version 2.0.28 or earlier may trigger a Settings Conflict when rediscovered after updating their firmware to version 2.1 or later. There is no issue with the device—there was simply a new property added in version 2.1. To dismiss the alert, resolve the Settings Conflict by selecting the properties you wish to keep.
  • The Timeline System Event “Active Transmitter Online” for ULXD6/8 transmitters does not always include Transmitter Device ID in the event description.
  • SLX and ULX frequencies in Master List mode cannot be manually entered in the Coordination Workspace. They can, however, be coordinated and analyzed.
  • While working in the RF Coordination or Frequency Plot, the scan data peaks change depending on horizontal zoom level.
  • In certain scenarios, the Frequency List dialog is empty and the CFL is not imported from AXT600.
  • While Timeline is running, markers will not display when changing FD-Override from the current state to a new state.

Notes

  • User Guide
  • Supported operating systems
    • Windows 10 and 11
    • macOS 10.15 (Catalina), 11 (Big Sur), 12 (Monterey)
  • To operate Wireless Workbench successfully, you must run it as an administrator. This includes when updating from within the application using Wireless Workbench version 6.13.1 or prior. Consult your IT department if you have questions about enabling administrator permissions on your computer.
  • Opening show files created with older versions of Wireless Workbench may result in the Settings Conflicts dialog opening once the file has loaded. This is due to newly supported hardware parameters that have been introduced with updated firmware versions. To maintain all settings from the show file, select "Keep all settings from: Wireless Workbench."
  • Alerts logged when devices first come online may list device parameters and their values as they are being discovered even though the parameter values themselves have not changed.
  • The ability to request replacement frequency band labels through the Frequency Band Conversion Tool and Report has been discontinued. The band conversion function is still available for use. For more information, please refer to the WWB Help System in the application, or contact Shure Applications Engineering.
  • To operate this version of Wireless Workbench with other Shure products, reference the following list of recommended versions:
    • Axient Digital 1.3.45
    • AD600 1.0.38
    • Axient 2.1.41
    • PSM1000 1.7.10
    • QLX-D 2.5.2
    • SLX-D 1.1.2
    • UHF-R 1.171
    • ULX-D 2.7.3
    • SBC220/240 Two-bay Chargers 1.3.45
    • SBC250/450/850 Networked Charging Stations 2.7.3
    • SBRC Shure Battery Rack Charger 1.1.6
    • Shure Update Utility 2.7.2
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
Software
4.7.2
23/09/2022 View All Updates

Important

  • New licenses are no longer being offered. For maintenance licenses, please contact your local Shure representative.

Bug Fixes

  • LDAP server configuration validation for port 636; password and username validation for port 389 errors during upgrade from SystemOn version 4.6.0 to 4.7.0

Pre-Upgrade Requirements

  • Designer and SystemOn cannot be installed on the same computer
  • Internet access is no longer required during the installation process; however, use of certain features like firmware updating and text notifications require internet access
  • After upgrading SystemOn, clear your browser cache on the device accessing the SystemOn server, then re-assign your licenses to your devices by navigating to your organization > Licenses > Start managing
  • SystemOn and Designer applications cannot be installed on the same computer; do not attempt to install one over the other
  • Before updating firmware, turn off “Device Missing” notifications, then turn them back on after completing the firmware updates

Platform Requirements

  • Supported Operating Systems
    • Windows Server 2019
    • Windows 10 (Professional or Enterprise), 64-bit edition
  • Supported Web Browsers
    • Chrome
    • Safari
    • Windows Edge
  • Hardware Minimum Requirements
    • 8 GB RAM (16 GB may be required when hundreds of devices are being accessed)
    • 2 GB hard disk
    • i5 dual-core processor

Notes

  • User Guide
  • To update firmware, please download Shure Update Utility
  • This version of SystemOn is compatible with the following recommended software and firmware versions:
    • IntelliMix Room 3.3.0
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.15
    • MXA910 4.7.13
    • MXA920 1.3.276
    • MXA-MUTE 1.5.16
    • MXN5-C 1.5.12
    • Microflex Wireless 10.0.6
    • P300 4.7.17
    • SBC220/240 1.3.45
    • SBC250/450/850 2.6.3
    • SCM820 1.4.3
    • ULX-D 2.6.3
Software
2.7.2
08/09/2022 View All Updates

Improvements

  • Support for the new AD600 – Axient® Digital Spectrum Manager
  • Support for added hardware revisions:
    • MXW Access Points
    • ULXD, QLXD, and SLXD transmitters

Known Issues

  • ULX-D devices running versions prior to 1.4.8 must be updated to 1.4.8 first before updating to 2.0.28. After 2.0.28 is installed, ULX-D devices can be updated to the latest available firmware version.  See ULX-D Firmware Update and Issues
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • Microflex Wireless devices running versions prior to 5.2.2 must be updated to 5.2.2 first before updating to a later firmware version.
  • Shure Update Utility may have unexpected behavior if the firmware files are in a directory location that contains Unicode characters.
  • In certain scenarios, the Shure Update Utility process is not terminated immediately on a Windows machine if you close the window while an update is in progress.
  • Shure Update Utility will fail to discover on first connection an ADX5D on Mac M1 machines running Big Sur.
    • Workaround: Restart your Mac computer and ADX5D will successfully be discovered.
  • When IP addresses are deleted from the remote devices list, the devices that have those IP addresses will still be discovered in the Update Devices tab.
    • Workaround: Restart Shure Update Utility

Important

  • In most cases, you should install the latest version of Shure Update Utility to update your devices. However, certain legacy devices require older versions of SUU:
    • Use Shure Update Utility 2.4.8 to update firmware on UHF-R, SHA900, KSE1500, and GLX-D systems or for 32-bit support.
    • Use Shure Update Utility 2.4.1 to update firmware on PSM1000 systems running firmware 1.1.0 or earlier.
    • Use the MXC Firmware installer to update MXC products, including DIS-CCU.
    • Use the DFR22 Software and a PC running Windows 8.1 or earlier to update a DFR22.
    • Update MOTIV and AONIC devices with their mobile or desktop apps.
  • Note: Installing SUU 2.4.8 and SUU 2.4.1 will replace the most recent version of SUU on your machine.

Notes

  • User Guide
  • Shure Update Utility is supported on the following operating systems:
    • Windows 10 and 11
    • macOS Catalina (10.15), Big Sur (11), and Monterey (12)
Software
1.8.5
01/08/2022 View All Updates

Improvements

  • Fixed issue with not displaying the latest firmware file in certain systems
  • Improved the upgrade process for devices with legacy firmware
  • Fixed issue with seeing the latest firmware file when a non-English language setting is used
Software
4.7.2
27/07/2022 View All Updates

Bug Fixes    

  • Resolved intermittent error condition associated with upgrading Designer from version 4.6.0 to 4.7.0 using network drives as the home drive
  • Resolved a persistent anomaly in which a MXA710 device configured as ceiling mount in the Routing page is visually presented as wall mount in the Coverage page

Pre-Upgrade Requirements

  • Requires one of the following operating systems:
    • Windows 10 (Professional or Enterprise), 64-bit edition
    • Windows 11 (Professional or Enterprise), 64-bit edition
  • This version of Designer is currently supported on PC only
  • Multiple versions of Designer cannot be installed on the same computer
  • Designer and SystemOn cannot be installed on the same computer

Upgrade Path

  • Designer versions 3.0 and 3.1 must be upgraded to 3.2 first, before upgrading to this version of Designer. Download Designer 3.2 here.
  • If you encounter an Installer failure during upgrade, allow the uninstaller process to finish, then restart installation
  • Export project files before upgrading Designer
  • Certain endpoint protection software may block the application, if you encounter this anomaly, whitelist the Designer installer or application

Known Issues

  • Dragging the PEQ filter curve rapidly for a long time will produce a delayed user response when using certain devices (MXA310, MXA910, MXA710, MXN5-C)
    • Workaround: Slow down drag and drop processes or manually key-in PEQ filter values
  • On the Coverage page when a device is selected and the property panel is visible, "Valid range" dialog numbers change when user clicks the +/- buttons on device height
  • When adjusting the device height on the Coverage Map, the Talker Height value may momentarily display a 0.01 meter change before settling.

Notes

  • User Guide
  • To update firmware, please download Shure Update Utility
  • Project files and database are not backward compatible with versions prior to 4.5
    • Templates saved in earlier versions of Designer are moved to a project named ‘Templates’ beginning in version 4.5.0
  • This version of Designer is compatible with the following recommended software and firmware versions:
    • IntelliMix Room 3.3.0
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.13
    • MXA910 4.7.13
    • MXA920 1.1.161
    • MXA-MUTE 1.5.15
    • MXN5-C 1.5.12
    • P300 4.7.11
Software
1.8.4
26/07/2022 View All Updates

Improvements

  • Incorporated Shure branding on the Stem ecosystem UI
Software
4.7.0
01/06/2022 View All Updates

Bug Fixes

  • In certain environments, user is unable to add cross-subnet devices using Add by IP feature
  • In the transmitter tab, ULXD transmitters display Battery health = 255% and Cycle count = 65535 when using non-Shure batteries
  • In the Monitoring view, ULXD transmitter battery status will display number of remaining minutes when below 15 minutes and it should display Empty
  • In certain network environments, when using 500 or more devices, some devices will not be discovered

Pre-Upgrade Requirements

  • Designer and SystemOn cannot be installed on the same computer
  • Internet access is no longer required during the installation process; however, use of certain features like firmware updating and text notifications require internet access
  • After upgrading SystemOn, clear your browser cache on the device accessing the SystemOn server, then re-assign your licenses to your devices by navigating to your organization > Licenses > Start managing
  • SystemOn and Designer applications cannot be installed on the same computer; do not attempt to install one over the other
  • Before updating firmware, turn off “Device Missing” notifications, then turn them back on after completing the firmware updates

Platform Requirements

  • Supported Operating Systems
    • Windows Server 2019
    • Windows 10 (Professional or Enterprise), 64-bit edition
  • Supported Web Browsers 
    • Chrome 
    • Safari 
    • Windows Edge 
  • Hardware Minimum Requirements
    • 8 GB RAM (16 GB may be required when hundreds of devices are being accessed)
    • 2 GB hard disk
    • i5 dual-core processor

Known Issues

  • When using a virtual machine, it’s recommended to dedicate hardware resources (HD, RAM, etc.) to the SystemOn application; using shared resources may cause Shure services to not start on reboot
  • When a device is being firmware updated, it will appear offline during the update in SystemOn
  • Discovering MXW microphones may take longer than 1 minute
  • UTC time and date are displayed on Event Log and Email/SMS notifications
  • For users setting up SMS notifications, the Senders Phone Number field does not show the required (*), but the field is required
  • If a valid license activation ID is applied and fails on the first attempt, please try again before calling support

Notes

  • User Guide
  • To update firmware, please download Shure Update Utility
  • This version of SystemOn is compatible with the following recommended software and firmware versions: 
    • IntelliMix Room 3.3.0
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.13
    • MXA910 4.7.13
    • MXA920 1.1.161
    • MXA-MUTE 1.5.15
    • MXN5-C 1.5.12
    • Microflex Wireless 10.0.6
    • P300 4.7.11
    • SBC220/240 1.3.26
    • SBC250/450/850 2.6.3
    • SCM820 1.4.3
    • ULX-D 2.6.3
Software
4.7.0
01/06/2022 View All Updates

New Features

  • Added support for the MXA920 Ceiling Array Microphone
  • IntelliMix Room remote firmware update
  • IntelliMix Room Long Lease Handling

Improvements  

  • Misconfigured devices are discoverable, but not configurable, to help identify network configuration issues
  • Improved Firmware mismatch handling between virtual and live devices
  • Device firmware package files are now stored in the same file location as Shure Update Utility

Bug Fixes    

  • User is unable to export project files after upgrading from Designer 4.5 to 4.6
  • If devices in a room are missing from the network, user is unable to open the room
  • No IntelliMix Room input channel meters are displayed after user mutes the Automix Out channel
  • P300 PEQ filter 1 default value was set to Low cut
  • In certain environments, installing Designer 4.5 would require PC Administrator rights during installation (Error 10 indication displayed)

Pre-Upgrade Requirements

  • Requires Windows 10 (Professional or Enterprise), 64-bit edition
  • This version of Designer is currently supported on PC only
  • Multiple versions of Designer cannot be installed on the same computer
  • Designer and SystemOn cannot be installed on the same computer

Upgrade Path

  • Designer versions 3.0 and 3.1 must be upgraded to 3.2 first, before upgrading to this version of Designer. Download Designer 3.2 here.
  • If you encounter an Installer failure during upgrade, allow the uninstaller process to finish, then restart installation
  • Export project files before upgrading Designer
  • Certain endpoint protection software may block the application, if you encounter this anomaly, whitelist the Designer installer or application

Known Issues

  • Dragging the PEQ filter curve rapidly for a long time will produce a delayed user response when using certain devices (MXA310, MXA910, MXA710, MXN5-C)
    • Workaround: Slow down drag and drop processes or manually key-in PEQ filter values
  • On the Coverage page when a device is selected and the property panel is visible, "Valid range" dialog numbers change when user clicks the +/- buttons on device height
  • When adjusting the device height on the Coverage Map, the Talker Height value may momentarily display a 0.01 meter change before settling.

Notes

  • User Guide
  • To update firmware, please download Shure Update Utility
  • Project files and database are not backward compatible with versions prior to 4.5
    • Templates saved in earlier versions of Designer are moved to a project named ‘Templates’ beginning in version 4.5.0
  • This version of Designer is compatible with the following recommended software and firmware versions:
    • IntelliMix Room 3.3.0
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.13
    • MXA910 4.7.13
    • MXA920 1.1.161
    • MXA-MUTE 1.5.15
    • MXN5-C 1.5.12
    • P300 4.7.11
Software
3.3.0
01/06/2022 View All Updates

Important

  • If you’re currently running IntelliMix Room 1.0, you must update to 2.0 first before installing 3.0 or later
  • To fully configure IntelliMix Room, download and install Shure Designer on a separate computer. Shure does not support installing Designer and IntelliMix Room on the same computer.

New Features and Improvements

  • Added the capability to update IntelliMix Room through Designer Software’s firmware update feature.
  • Added logic device type and EQ contour support for the MXA920 Ceiling Array Microphone.
  • IntelliMix Room now supports Windows 11.
  • Reduced the CPU consumption of the AI Denoiser feature.
  • Reduced the CPU consumption of IntelliMix Room when the Acoustic Echo Cancellation (AEC) and Noise Reduction (NR) features are disabled.
  • Revised the system requirements needed to support IntelliMix Room.
  • Improved the behavior of IntelliMix Room after a paid license has expired. After the grace period, there will be periodic visual and audible license expiration notifications to the user, rather than audio being muted.
  • Added the ability to view the Network Interface Card (NIC) used for license verification within the IntelliMix Room licensing settings page.
  • Improved the user experience to clarify which version of IntelliMix Room was preserved on the computer when canceling an upgrade and performing a “roll back”.
  • Removed Network Throttling as an optional Windows optimization. Instead, Network Throttling is automatically disabled on computer startup. Network Throttling left “on” is known to cause audio performance issues in some scenarios.

Bug Fixes

  • Resolved issues where many audio soundcards connected to the IntelliMix Room host computer could prevent discovery within Designer Software.
  • Resolved issues where audio transmission could be delayed up to 5 minutes after PC restart when using Realtek PC Output devices with Kiosk-type devices.
  • Resolved issues where mute synchronization between IntelliMix Room and the software codec could stop working if the computer was restarted via the removal of the power cable.

Known Issues

  • Packet scanning security software may cause audio performance issues with IntelliMix Room.
  • In order to transition from a trial license to a paid license before trial expiration, the IntelliMix Room endpoint must be deactivated and reactivated. Otherwise, the entire trial license term will be used before the paid license.
  • When renewing a license, IntelliMix Room will use the 90-day grace period of the expired license before activating the new, renewed license. After the grace period ends, the new license will automatically activate and the expiration message in the user interface will disappear.
  • The USB Mute Synchronization and Call Status features do not properly reflect LED statuses when joining third-party meetings from Microsoft Teams Rooms (MTR) devices.
  • In scenarios where many NICs are connected to the IntelliMix Room host computer, IntelliMix Room may not be discoverable in Designer software. Remove or disable some of the NICs to enable discovery in Designer software.
  • In scenarios where many audio soundcards are connected to the IntelliMix Room host computer, some of the connected devices may be truncated from PC Input or Output list views within Designer Software. Shure recommends removing or disabling the unneeded audio soundcards.
  • Changing the System Name of the host computer after installation of IntelliMix Room also changes the Dante Device name in Dante Controller. The Shure device name stays the same. Changing the Dante Device name can impact audio routes to Dante receive devices.
  • Ensure that the system/device name of the computer running IntelliMix Room is unique and follows Microsoft’s recommendation of 15 characters or less. IntelliMix Room relies on this unique name for proper Shure and Dante network operation.
  • Allowing a system running IntelliMix Room to enter a sleep state can cause issues with IntelliMix Room’s logic and mute synchronization functionality. A restart of the computer resolves the issue.
  • In some scenarios when using Dante Domain Manager with Shure devices, IntelliMix Room may appear as “Dante Locked” regardless of the device permissions set in Dante Domain Manager. In this state, IntelliMix Room networked audio settings cannot be customized. To resolve this, unenroll and reenroll IntelliMix Room within Dante Domain Manager.

Notes

  • User Guide
  • Installation and Deployment Guide
  • Quick Start Guide
  • This version of IMX Room is compatible with the following recommended software and firmware versions:
    • Designer 4.7.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.13
    • MXA910 4.7.13
    • MXA-MUTE 1.5.15
    • Microflex Wireless 10.0.6
    • P300 4.7.11
Software
1.7.10
20/05/2022 View All Updates

Improvements

  • App optimization
  • Internal fixes
  • General improvements