Firmware
2.5.0
July 1, 2021
View All Updates
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
Improvements
- NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
- MODEL - Name of the receiver model
- TX_FW - Firmware version of the received transmitter
- Support added for new ULXD4D/Q devices which ensure that encryption is used
- At this time, AXT600 Spectrum Manager does not support always encryption DCID
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
- SBC250/450/850 Networked Charging Stations 2.4.13
- Axient AXT600 Spectrum Manager 2.1.38
- Wireless Workbench 6.14.1
- Shure Update Utility 2.6.1
- ShurePlus Channels 1.4.6
Firmware
2.5.0
July 1, 2021
View All Updates
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvements
- NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
- MODEL - Name of the receiver model
- TX_FW - Firmware version of the received transmitter
- Support added for new ULXD4D/Q devices which ensure that encryption is used
- At this time, AXT600 Spectrum Manager does not support always encryption DCID
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
- SBC250/450/850 Networked Charging Stations 2.4.13
- Axient AXT600 Spectrum Manager 2.1.38
- Wireless Workbench 6.14.1
- Shure Update Utility 2.6.1
- ShurePlus Channels 1.4.6
Firmware
2.5.0
July 1, 2021
View All Updates
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvements
- NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
- MODEL - Name of the receiver model
- TX_FW - Firmware version of the received transmitter
- Support added for new ULXD4D/Q devices which ensure that encryption is used
- At this time, AXT600 Spectrum Manager does not support always encryption DCID
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
- SBC250/450/850 Networked Charging Stations 2.4.13
- Axient AXT600 Spectrum Manager 2.1.38
- Wireless Workbench 6.14.1
- Shure Update Utility 2.6.1
- ShurePlus Channels 1.4.6
Firmware
2.6.3
May 24, 2022
View All Updates
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvements
- Support for added hardware revisions
Known Issues
- Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.6.3
- SBC250/450/850 Networked Charging Stations 2.6.3
- Axient AXT600 Spectrum Manager 2.1.38
- Wireless Workbench 6.15.0
- ShurePlus Channels iOS 1.5.2
- ShurePlus Channels Android 1.1.1
- Shure Update Utility 2.7.1
Firmware
2.6.3
May 24, 2022
View All Updates
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvements
- Support for added hardware revisions
Known Issues
- Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.6.3
- SBC250/450/850 Networked Charging Stations 2.6.3
- Axient AXT600 Spectrum Manager 2.1.38
- Wireless Workbench 6.15.0
- ShurePlus Channels iOS 1.5.2
- ShurePlus Channels Android 1.1.1
- Shure Update Utility 2.7.1
Firmware
2.6.3
May 24, 2022
View All Updates
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Improvements
- Support for added hardware revisions
Known Issues
- Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.6.3
- SBC250/450/850 Networked Charging Stations 2.6.3
- Axient AXT600 Spectrum Manager 2.1.38
- Wireless Workbench 6.15.0
- ShurePlus Channels iOS 1.5.2
- ShurePlus Channels Android 1.1.1
- Shure Update Utility 2.7.1
Firmware
2.7.3
October 4, 2022
View All Updates
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Known Issues
- Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.7.3
- Axient AXT600 Spectrum Manager 2.1.41
- SBC250/450/850 Networked Charging Stations 2.7.3
- Shure Update Utility 2.7.2
- ShurePlus Channels iOS 1.5.2
- ShurePlus Channels Android 1.1.1
- Wireless Workbench 6.15.0
Firmware
2.7.3
October 4, 2022
View All Updates
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Known Issues
- Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.7.3
- Axient AXT600 Spectrum Manager 2.1.41
- SBC250/450/850 Networked Charging Stations 2.7.3
- Shure Update Utility 2.7.2
- ShurePlus Channels iOS 1.5.2
- ShurePlus Channels Android 1.1.1
- Wireless Workbench 6.15.0
Firmware
2.7.3
October 4, 2022
View All Updates
Important
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Known Issues
- Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
- ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.7.3
- Axient AXT600 Spectrum Manager 2.1.41
- SBC250/450/850 Networked Charging Stations 2.7.3
- Shure Update Utility 2.7.2
- ShurePlus Channels iOS 1.5.2
- ShurePlus Channels Android 1.1.1
- Wireless Workbench 6.15.0
Firmware
2.7.6
February 16, 2023
View All Updates
Improvements
- Fixed distorted audio issue on ULXD4 devices with Dante version REV3
- Fixed issue where ULXD4 devices sometimes disappear from Wireless Workbench® and do not reconnect
Important
- ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
- ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
- After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
- ULX-D devices that are downgrading to 1.5.6 may report a false failure.
- Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
- ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.
Known Issues
- Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions
Notes
- User Guide
- ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
- Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
- Align the infrared ports with the transmitter
- Press ENTER
- To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
- ULXD1/2/6/8 Transmitters 2.7.3
- ULXD4/4D/4Q Receivers 2.7.6
- Axient AXT600 Spectrum Manager 2.1.41
- SBC250/450/850 Networked Charging Stations 2.7.3
- Shure Update Utility 2.8.0
- ShurePlus Channels iOS 1.6.0
- ShurePlus Channels Android 1.6.0
- Wireless Workbench 6.15.3