Downloads

Software & Firmware Archives

Filter by update type

Type

Release Title

Latest Version

Associated Products

Download

Firmware
2.6.3
May 24, 2022 View All Updates

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Support for added hardware revisions

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.6.3
    • SBC250/450/850 Networked Charging Stations 2.6.3
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.15.0
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
    • Shure Update Utility 2.7.1
Firmware
2.6.3
May 24, 2022 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Support for added hardware revisions

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.6.3
    • SBC250/450/850 Networked Charging Stations 2.6.3
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.15.0
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
    • Shure Update Utility 2.7.1
Firmware
2.6.3
May 24, 2022 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Support for added hardware revisions

Known Issues

  • Group Scan Deployment and Custom Group Load may not work with other ULXD4/ULXD4D/ ULXD4Q that are running older firmware versions

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate this version of ULX-D devices with other Shure networked systems and software, see the following list of recommended versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.6.3
    • SBC250/450/850 Networked Charging Stations 2.6.3
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.15.0
    • ShurePlus Channels iOS 1.5.2
    • ShurePlus Channels Android 1.1.1
    • Shure Update Utility 2.7.1
Firmware
2.5.0
July 1, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0
July 1, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0
July 1, 2021 View All Updates

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.4.25
February 17, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Changed the default RF band from AB to JB for ULXD4=-AB receivers
  • Add support for China 470 MHz – 510 MHz frequency band (G53)

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    • Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    • Align the infrared ports with the transmitter
    • Press ENTER
  • To operate ULX-D version 2.3.25 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.25
    • SBC250/450/850 Networked Charging Stations 2.4.9
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • PSM1000 1.7.10
    • Axient AXT600 Spectrum Manager 2.1.31
    • Wireless Workbench 6.14.0
    • Shure Update Utility 2.5.1
    • ShurePlus Channels 1.4.5
Firmware
2.4.25
February 17, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Changed the default RF band from AB to JB for ULXD4=-AB receivers
  • Add support for China 470 MHz – 510 MHz frequency band (G53)

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    • Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    • Align the infrared ports with the transmitter
    • Press ENTER
  • To operate ULX-D version 2.3.25 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.25
    • SBC250/450/850 Networked Charging Stations 2.4.9
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • PSM1000 1.7.10
    • Axient AXT600 Spectrum Manager 2.1.31
    • Wireless Workbench 6.14.0
    • Shure Update Utility 2.5.1
    • ShurePlus Channels 1.4.5
Firmware
2.4.25
February 17, 2021 View All Updates

Important

  • ULXD4D and ULXD4Q receivers running firmware prior to 1.4.8 must be updated to 1.4.8 before updating to newer versions.
  • ULXD4D and ULXD4Q receivers running firmware between 1.4.8 and 2.0.28 must be updated to 2.0.28 before updating to newer versions.
  • After 2.0.28 is installed, ULXD4D and ULXD4Q receivers can be updated to the latest available firmware version.
  • ULX-D devices that are downgrading to 1.5.6 may report a false failure.
    • Workaround: Because this is a false failure, closing the send updates window and going to the main page, Shure Update Utility will show green for the firmware version.
  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Changed the default RF band from AB to JB for ULXD4=-AB receivers
  • Add support for China 470 MHz – 510 MHz frequency band (G53)

Notes

  • User Guide
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    • Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    • Align the infrared ports with the transmitter
    • Press ENTER
  • To operate ULX-D version 2.3.25 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.25
    • SBC250/450/850 Networked Charging Stations 2.4.9
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • PSM1000 1.7.10
    • Axient AXT600 Spectrum Manager 2.1.31
    • Wireless Workbench 6.14.0
    • Shure Update Utility 2.5.1
    • ShurePlus Channels 1.4.5
Firmware
2.4.9
November 11, 2019 View All Updates

New Features

  • Dante ™ update to software version 4.2.1.1 and firmware version 4.0.2.9

Improvements

  • The lock setting for the front panel SCAN button now prevents frequency changes due to group scans initiated by other ULXD4 units
  • Support for additional RF bands:
    • Thailand 694 – 703 MHz frequency band (M19)
    • Thailand 748 – 758 MHz frequency band (Q12)
  • Bug fixes

Notes

  • User Guide
  • To operate ULX-D version 2.4.9 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.4.9
    • SBC250/450/850 Networked Charging Stations 2.3.6
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
    • PSM1000 1.6.21
    • Axient AXT600 Spectrum Manager 2.1.22
    • Wireless Workbench 6.13.1
    • Shure Update Utility 2.4.6
    • ShurePlus Channels 1.4.2