Firmware

DDS 5900 and DCS 6000

Versions

Date Posted

Download

9.4.0
December 15, 2021

Release notes cover the following models:

  • MXC605/605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • AO6004
  • DC5900F
  • DC5980P
  • DCS6000 legacy conference and interpreter units

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit and to update DC5900F and DC5980P devices to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release, is required to be used making the update.

New Features

  • MXCIC
    • Option to select microphone (headset or gooseneck) at headset insertion
  • MXC640
    • ‘Chairman' changed to 'Chairperson'

Bug Fixes

  • MXC640
    • Interpreter channels are not updating
    • The unit continues to show speech time, when speech time is paused, and then no speech time is selected
    • Voting result is wrong with large voting weight
    • Wrong vote conclusion is shown after entering votes manually from CUA
    • NFC card remove/insert during voting in 'Meeting mode: Using chip card authentication’ is failing
    • When chairperson turns off microphone other delegates seated on MXC640 units, have their speech time set to 00:00
    • Keeps showing delegate speech time after switching to group speech time
  • MXCIC
    • Enable MIU interpreter source can occupy unused outgoing channels on MXCIC units
  • MX605
    • Enable MIU interpreter source can block all outgoing channels on MXC605 Int.

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with FW release 9.4.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 v9.2 or later
    • Shure NFC Programming App 1.0.3
9.3.0
June 30, 2021

Release notes cover the following models:

  • MXC605/605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • AO6004
  • DC5900F
  • DC5980P
  • DCS6000 legacy conference and interpreter units

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit and to update DC5900F and DC5980P devices to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release, is required to be used making the update.

New Features

  • MXC640
    • Optimization of voting performance (card insert/remove):
      • When the participant inserts the card, an animation 'Reading NFC card' is shown following with displaying of the name of the participant logging in. The animation is still shown when a participant is logging in, when a voting session is not started, but is fast-forwarded and greeting-banner removed, when a voting session is started enabling the participant to vote as quick as possible after inserting the card.
  • DIS-CCU
    • ‘System information’ report updated to include firmware version of devices
    • Chairman' changed to 'Chairperson'

Bug Fixes

  • DIS-CCU
    • The FW version number reported with the 'avr' command is different compared to FW version reported in FUU
    • Event log warning added if unknown card is detected
  • MXC640
    • Removal of wrong NFC card during SW6000 meeting & voting, results in card-error-animation hang
    • Wrong voting conclusion (passed/not passed) can be displayed when under SW6000 control

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with FW release 9.3.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 v9.2 or later
    • Shure NFC Programming App 1.0.3
9.2.3
June 23, 2021

Release notes cover the following models:

  • MXC605/605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • AO6004
  • DC5900F
  • DC5980P
  • DCS6000 legacy conference and interpreter units

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit and to update DC5900F and DC5980P to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release, is required to be used making the update.

New Features

  • This is a hotfix and does not include any new features. Please refer to ‘Release Note 9.2.0’ for a list of new features in FW 9.2.

Bug Fixes

  • MXC620/620-F, MXC630/630-F, MXC640
    • A bug is corrected, where the NFC card, art. no. ‘MXCNFCCard-10PK’, did not work in the units.
  • MXCIC
    • A bug is corrected, where units randomly did not respond to system changes (language channels etc.) and where the microphone list was not shown.

Known Issues

  • For a list of known issues please refer to ‘Release Note 9.2.0’ for a list of new features in FW 9.2.

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with FW release 9.2 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 v9.2 or v9.3
    • Shure NFC Programming App 1.0.3
9.2.2
May 26, 2021

Release notes cover the following models:

  • MXC605/605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • AO6004
  • DC5900F
  • DC5980P
  • DCS6000 legacy conference and interpreter units

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit and to update DC5900F and DC5980P to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release must be usedtoupdate your firmware.

New Features

  • This is a hotfix and does not include any new features. Please refer to the version 9.2.0 release notes for a list of new features in FW 9.2.

Bug Fixes

  • MXC605
    • A bug is corrected where audio was not present in the loudspeaker in the unit when the MXC605 was configured as a voting unit.

Known Issues

  • For a list of known issues please refer to ‘Release Note 9.2.0’ for a list of new features in FW 9.2.

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with FW release 9.2.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 v9.2
    • Shure NFC Programming App 1.0.3
9.2.0
February 11, 2021

Release notes cover the following models:

  • MXC605/605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • AO6004
  • DC5900F
  • DC5980P
  • DCS6000 legacy conference and interpreter units

Important

  • This firmware release can be used to update:
    • Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit
    • DC5900F and DC5980P to register and work in an MXC system
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release
  • The update requires using the Firmware Update Utility (FUU) included in this release

New Features

  • System
    • Support for Mifare/Desfire card when used with SW6000
      • When using SW6000, the MXC system can now be configured to provide:
        • The User ID/Login code data from ACOS3 NFC cards programmed from SW6000 (current feature) or
        • The Unique ID on a Mifare/Desfire NFC card or an ACOS3 NFC card (new feature)
      • Benefits
        • Using the Unique ID enables usage of cards where no (meeting) data has been written to the card
        • This makes it possible to use cards that are provided to users for other purposes to login to SW6000, so the user needs to hold one less card
      • Important
        • Mifare/Desfire NFC cards can only be used with SW6000 connected, not in a standalone system
  • DIS-CCU
    • Support for setting output/level on the AO6004 Audio Output unit
    • Additional languages – Polish & Croatian
    • System Information Report – Information content updated
    • Support for configuring MXCMIU as Interpreter source
    • Support for configuring MXC605 as a voting unit
    • Alternate LED indications. Option to set the microphone ‘Speak/Request color’:
      • Red speak | Green Request
      • Green speak | Green Request
    • Option to disable the Request indication in the gooseneck microphone
    • Disable Global language selection (CGUI) when SW6000 is connected
  • MXCMIU
    • Interpreter Source option
  • MXC640
    • Additional languages – Polish & Croatian
    • Expand Agenda Prefix
  • MXC605
    • Option with new overlay: Voting 2- and 3-buttons, Attendance check, Secret/open voting
  • MXCIC
    • Expand Agenda Prefix
  • MXCSIGN
    • OS updated to allow the use of the USB connector together with the ‘Shure MXCSIGN App’. The app allows to transfer a defined picture to the sign
  • TPCI
    • ‘Speak Slow’ support
    • MIU interpreter source option

Bug Fixes

  • System
    • Ambient sound disappears when switching to VOX mode
  • CCU
    • Web GUI removes only a single unregistered unit at 'Remove unregistered units'
    • Web GUI – Indication in buttons in Diagnostic screen updated
    • Diagnostic – last unit on a chain is reported as lost when reconfigured into loop
    • Floor1 and Floor2 is switched in the web GUI Channel-dropdown
    • Force CCU-configuration to 1000 m of cable, when upgrading from earlier versions to Release 9.2.0
    • The indication for 605 interpreter in 'Diagnostic' is wrong
  • MXCMIU
    • Function button indication is not turning blue, when configured as ambient mic
  • MXC620
    • Unit not reacting to card inserted, when location code is altered
  • MXC620-F & MXC630-F
    • Chairman left button configured as Exclusive can take over other units already in Exclusive state
  • MXC630 and MXC630-F
    • 3-Btn Secret voting with proxy – missing LED indication
    • Cannot login to a meeting during a paused Voting session
    • Indication in proxy button is not correct
    • Secret voting – wrong LED indication
  • MXC640
    • "Attended" text is not translated
    • Misleading texts corrected when logging in with card
    • Missing clear feedback on buttons on login screen
    • Present/seats value = 2000 are cut of in right side, and only 200 is shown
    • Speech time display permissions are not working
    • Voting not possible with meeting mode: No login
  • MXCIC
    • Some units are 'Locked' when the system is powered
    • Unable to turn off "Audible Level Warning"

Known Issues

  • Manually entered voting results are not shown if a normal voting session has not been started first
  • The agenda subject name for a manually entered result may be wrong
  • It is not possible to use an MXC640 configured as dual delegate with SW6000 if the use of NFC cards is enabled

Notes

  • These release notes include notes from the not-released FW 9.1
  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with FW release 9.2 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 9.2.0
    • Shure NFC Programming App 1.0.3
9.0.2
September 29, 2020

Release notes cover the following models:

  • MXC605
  • MXC605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • DC5900F
  • DC5980P

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCUCentral Unit and to update DC5900F and DC5980P to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release, is required for the update.

New Features

  • This is a hotfix – no new features. Refer to release note for Release 9.0.0 for description of new features.

Bug Fixes

  • Incorrect Default CCU-database when upgrading a former 5900-system (2000 m cable instead of default 1000m) leading to communication problems using short feeding cables.
  • Updating of CCU from 8.6.2 (in 5900-mode) must force 6000-mode LAN configuration

Known Issues

  • Refer to the release notes for Release 9.0.0 for description of known issues.

Notes 

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with version 9.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 9.0.13
    • Shure NFC Programming App 1.0.3
9.0.0
August 3, 2020

Release notes cover the following models:

  • MXC605
  • MXC605-F
  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN
  • DIS-CCU
  • DC5900F
  • DC5980P

Important

  • This firmware release can be used to update Microflex Complete (MXC) or DCS 6000 systems using DIS-CCU Central Unit and to update DC5900F and DC5980P to register and work in an MXC system.
  • Systems using CU 5905, CU 6000, CU 6005, CU 6010, CU 6011, CU 6105, or CU 6110 Central Units are not supported in this release.
  • The Firmware Update Utility (FUU) included in this release, is required to make the update.

New Features

  • DIS-CCU  
    • MXC605 support – as delegate, chairman, ambient and interpreter
    • MXC605-F support – as delegate, chairman and ambient
    • DC5980P support for use in MXC system – as delegate, chairman and interpreter
      • Meeting role (Delegate/Chairman) is set in DIS-CCU  -  change "on-the-fly"
      • Left button is configured in DIS-CCU
        • Delegate: No function or Mute
        • Chairman: No function or All delegates off
    • DC5900F support for use in MXC system – as delegate and chairman
      • Meeting role (Delegate/Chairman) is set in DIS-CCU  -  change "on-the-fly"
    • Auto registration/selection of MXC VOX mode vs 6000 VOX mode. If 5900/6000 units are present, voice activation mode will be 6000 VOX mode, otherwise it will be MXC VOX mode
    • Comply with California’s IoT Law
    • Global and UI language options expanded with Catalan and Basque
    • System change option between 5900 and 6000 mode removed
    • FL6000 license included as default
  • MXC Conference Units
    • Support for Speak button “Delegate speak button lock”
    • Support for Speak button "Press and hold"
    • UI language options expanded with Catalan and Basque
  • MXCIC
    • Option to show agenda
    • Option to enable/disable the audio beeps for hearing protection
    • Mic LED button behavior to indicate selected outgoing channels status
  • TCPI
    • 'mic_mute_all’ command included

Bug Fixes

  • MXC Conference units
    • MXC VOX mode: Pressing Mute should prevent gating on own MIC
  • MXC630-F 
    • Wrong indication in 'Abstain' button
  • MXC640
    • Fixed LED control when a dual unit is both in speak list and request list
    • Present/seats value = 2000 was cut off on right side, and only 200 was shown
    • Home screen and FW upgrade screen images are changed
  • MXCMIU
    • Individual microphone Level was not persistent across unit and CCU reset
  • MXCIC 
    • Long participant names were not updating on Speakers page
  • TPCI 
    • Individual vote state was missing a space char before button_id
    • Mic_speech_time_alarm repeats multiple times for alarm for each unit
    • Mix-minus state info was not correct
  • Legacy 6000 units
    • VOX settings not kept after reboot

Known Issues

  • MXC640
    • Manually entered voting results are not shown if a normal voting session has not been started first
    • The agenda subject name for a manually entered result may be wrong
    • It is not possible to use an MXC640 configured as dual delegate with SW6000 if the use of NFC cards is enabled

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices using version 9.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 v9.0
    • Shure NFC Programming App 1.0.3
8.6.0
February 11, 2020

Important

  • This firmware release can be used to update Microflex Complete (MXC), DCS 6000, or DCS 5900 systems using DIS-CCU, CU 5905, CU 6105, or CU 6110 Central Units.
  • Systems using CU 6000, CU 6005, CU 6010 and CU 6011 Central Units are not supported in this release.
  • The Firmware Upgrade Utility (FUU) which is included in the release, is required to update MXC devices.

New Features

  • MXCSIGN features in CCU standalone operation:
    • The sign content to be shown can be selected either from the ‘Participant list/NFC’ or from a separate list with ‘Text lines’
    • Option to change font size
  • MXCSIGN
    • Support for all alphabets (including complex alphabets) used in the MXC global languages
    • Hebrew is supported when used with SW6000
  • Voice activation functionality with time compression in MXC conference units
  • Mix-minus functionality in loudspeaker in MXC conference units
  • TPCI additions:
    • Meeting start/stop
    • Autofloor on/off
    • Speech time alarm
    • Reporting of participants individual votes
    • MXCSIGN support
      • Control of the content in standalone systems
      • Support for pairing the MXCSIGN to a seat
      • Import of content into the text lines for MXCSIGN
  • MXCMIU: Ambient support

Bug Fixes

  • MXCSIGN
    • SW6000/MXCSIGN: Disconnecting-connecting a sign gives an error message

Known Issues

  • MXC640
    • Manually entered voting results are not shown if a normal voting session has not been started first
    • The agenda subject name for a manually entered result may be wrong
    • It is not possible to use an MXC640 configured as dual delegate with SW6000 if the use of NFC cards is enabled

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with version 8.6.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • SW6000 6.10.14
    • Shure NFC Programming App 1.0.3
8.3.1
June 14, 2018

Important

  • This firmware release can be used to upgrade units in a DDS 5900 or a DCS 6000 systems using CU 5905, CU 6105, CU 6110 or DIS CCU Central Units.
  • CU 6000, CU 6005, CU 6010 and CU 6011 Central Units are not supported in this release.
  • DIS FUU Firmware Upgrade Utility is required to upgrade devices.

New Feature

  • DCS 6000 (DIS CCU) and CU61XX: Support for Microflex Complete MXC615, MXC620, MXC620-F, MXC630, and MXC630-F

Improvements

  • Bug fixes for DC 6990 P
  • Delegate devices incorrectly handles Mic On in Manual + Reply Mode
  • Speech time is not reset after microphone is turned off
  • Devices may not display delegate name on Welcome screen
  • Exclusive requests behave incorrectly between two devices set as Chairman

Notes

8.2.2
November 23, 2017

Important

  • This firmware release can be used to upgrade units in a DDS 5900 or a DCS 6000 systems using CU 5905, CU 6105, CU 6110 or DIS CCU Central Units.
  • The CU 6000, CU 6005, CU 6010 and CU 6011 Central Units are not supported in this release.
  • The DIS FUU Firmware Upgrade Utility, which is part of this firmware release, must be used when upgrading

New Features

  • CU/CUU: Added multi-language support for WEB-UI and Name Sign.
  • CU 5905/CCU(5900 mode) - Support for TPCI mic_attenuation command

Improvements

  • CU/CCU - Ensures channel selectors get language abbreviation on/off setting repeatedly.
  • SW6000, CU – Fixed the clearing request list so that the individual request Off comes before Clear Request List
  • CU/CCU - Fixed CU response with Mic on, when sending microphone on message to an Interpreter that is not connected to the CU
  • CU/CCU - CU is no longer resetting if interpreter settings are reset while the interpreter microphone is active
  • CU/CCU - WEB-UI "View Open Source Licenses" now shows open source licenses instead of a "404 Not Found" html page
  • CS6340F - After CU starts up, channel OLED on CS6340F now correctly shows channel language abbreviation instead of channel number
  • IS6132 – There is no longer an audible difference in sound level on CU audio output, when comparing floor sound and interpreted audio
  • SW6000, Interpreter, CU61xx, - Interpreter status is now correctly marked as "Lost" if unregistered rather than "Not Lost" and leading to wrong status in SW6000
  • DC59xx – Fixed the "All delegate off" LED so that it is not ON when the button is pressed on DC59xx chairman units
  • CU/CCU – In operation mode FIFO, the request list is now restored to speak list when selecting "All del off" on the WEB-UI

Notes

8.2
March 31, 2017

IMPORTANT

  • This firmware release can be used to upgrade units in a DDS 5900 or a DCS 6000 systems using CU 5905, CU 6105, CU 6110 or DIS CCU Central Units.
  • The CU 6000, CU 6005, CU 6010 and CU 6011 Central Units are not supported in this release.
  • The DIS FUU Firmware Upgrade Utility, which is part of this firmware release, must be used when upgrading

NEW FEATURES

  • Support of Shure Name Sign
  • Support for individual microphone attenuation control in 5900 mode on the CU/CCU GUI
8.0.5
October 18, 2016

NEW FEATURES

  • DC6990P - Support for colours on voting buttons
  • 6000, 5900 - Support for "Speak Button Lock". Settings available from CU5905/CU6110/CCU web interface. The ‘Lock Override Time (Long Push Time)’ and the ‘Lock Duration’ is settable from the web interface.
  • 6000, 5900 - Support for "Allow Mic Off". Settings available from CU5905/CU6110/CCU web interface
  • DC6990, DC6190, DM6680, DC59xx - Support for "Long Push" to overrule Speak Button Lock

IMPROVEMENTS

  • CU5905/CU6110/CCU – Audio In Volume, Level & Muted settings were not stored correctly in CU configuration. Making changes to Audio In 1 caused changes to be used for Audio In 2 after next reboot and vice versa
  • CU61xx, CCU - Electrical clicking noise removed from interpreter microphone LED when microphone is activated
  • CU5905/CU6110/CCU – Setting Audio In2 -> Loudspeaker from front plate does not work
  • CU61xx, CCU - Setting an Interpreter Unit to same A and B outgoing channel will cause audio to become lost if interpreter switch outgoing channel between A and B with Interpreter Unit engaged
  • PCB6000 (Flush mounted units) - Vote LED indication not correctly updated on chip card login during voting session if user has voted previously in the same session
  • DC6990P – Speech time not stopped on delegates during Exclusive On
  • DC6990P – Seat names not updated correctly on unit type change

FIRMWARE UPGRADE UTILITY (FUU) V1489

  • An issue in FUU was fixed where units with old firmware were cleared on a CU6010 when they became locked - hereby preventing an upgrade. (CONFFW-558)
  • Timestamps added to Upgrade Log.
  • FUU will now by default look for a FUU library in a the released folder structure.
7.5.10
October 2, 2015

IMPROVEMENT

DC6120P - fixed bug causing missing audio on DC6120 units

Associated products

DCS 6000

A flexible and powerful system that can conform to the specific needs or protocols of any group or organization, from city councils to global enterprises.

DDS 5900

Enable meeting participants to hear each other clearly, across the room or country. Portable & installed units combine audio & user controls in an integrated system.

Microflex® Complete

From a 20-person board meeting to an international assembly of thousands, the Microflex® Complete conference system keeps the conversation productive.