Firmware

P300-IMX IntelliMix Audio Conferencing Processor

Versions

Date postée

Téléchargement

6.0.38
February 29, 2024

Improvements

  • Enhancements to support Designer 6.0.0
  • Additional hardware support

Known Issues

  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300 with Microsoft Teams, reference the following minimum versions: 
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300 with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 6.0.0
    • ANI22/ANI4IN/ANI4OUT 6.0.41
    • ANIUSB 6.0.44
    • MXA310 6.0.23
    • MXA710 6.0.24
    • MXA910 6.0.24
    • MXN5-C 6.0.17
    • MXA-MUTE 6.0.25
    • MXW 10.0.X
    • Shure Update Utility 2.8.4
    • Shure Web Device Discovery 1.2.17
4.7.24
January 12, 2024

Improvements

  • General backend improvements

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.35
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.23
    • MXA310 4.7.8
    • MXA710 1.5.16
    • MXA910 4.7.13
    • MXN5-C 1.5.21
    • MXA-MUTE 1.5.23
    • Microflex Wireless 10.0.8
    • Shure Update Utility 2.8.3
    • Shure Web Device Discovery 1.2.17
4.7.21
March 15, 2023

Improvements

  • Support for added hardware revisions

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.15
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.21
    • MXA310 4.7.8
    • MXA710 1.5.16
    • MXA910 4.7.13
    • MXN5-C 1.5.21
    • MXA-MUTE 1.5.17
    • Microflex Wireless 10.0.8
    • Shure Update Utility 2.8.1
    • Shure Web Device Discovery 1.2.17
4.7.17
September 9, 2022

Improvements

  • Bug fixes

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.2
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.17
    • MXA310 4.7.8
    • MXA710 1.5.14
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.16
    • Microflex Wireless 10.0.6
    • Shure Update Utility 2.7.2
    • Shure Web Device Discovery 1.2.17
4.7.14
June 22, 2022

Improvements

  • General enhancements

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has a brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically adds new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.14
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.15
    • Microflex Wireless 10.0.6
    • Shure Update Utility 2.7.1
    • Shure Web Device Discovery 1.2.17
4.7.11
June 1, 2022

New Features

  • Device Type – Informs supporting USB-connected codecs the P300 will or will not handle AEC (acoustic echo cancellation). The user or the codec* can then enable or disable the codec’s AEC. *Certified Codecs may support automatic AEC disable or enable based on the device type. Users may also manually enable or disable AEC with supporting codecs.
    • Speakerphone: Use when the codec will handle AEC.
    • Echo-canceling speakerphone: Use when the P300 will handle AEC.
    • Designer’s Optimize workflow chooses Echo-cancelling speakerphone by default.
    • USB device type changes take 3-4 seconds and audio drops out briefly. Do not change other settings while this takes effect.
    • It may be required to select the P300-IMX as the default audio device in the codec after making changes.
  • Added logic device type and EQ contour support for the MXA920 Ceiling Array Microphone

Improvements

  • Bug fixes

Known Issues

  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically add new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of recommended versions supported:
    • Designer 4.7.0
    • ANI22/ANI4IN/ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA710 1.5.13
    • MXA910 4.7.13
    • MXN5-C 1.5.12
    • MXA-MUTE 1.5.15
    • Microflex Wireless 10.0.6
    • Shure Update Utility 2.7.1
    • Shure Web Device Discovery 1.2.17
4.6.6
November 5, 2021

New Features

  • Disable USB Mute Sync communication with software codec platforms

Improvements

  • Improved gain, audio routing, and EQ contour settings when using the Designer “Optimize” feature with P300 and Shure microphones
  • Bug fixes

Known Issues

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically add new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.6.0
    • ANI22/ANI4IN/ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • MXA710 1.4.2
    • MXN5-C 1.4.3
    • MXA-MUTE 1.4.4
    • Microflex Wireless 9.0.4
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
4.5.13
September 15, 2021

New Features 

  • Services – ability to configure network services

Improvements 

  • USB mute sync stability
  • Bug fixes

Known Issues 

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1+ firmware to use this feature
  • P300 Shure Audio Encryption sometimes has brief crackling sound on audio after muting
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.
  • P300 firmware periodically add new properties. The P300 may become undiscoverable if downgrading to firmware without the new properties and may need a factory reset to become discoverable.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes 

  • User Guide
  • Command Strings
  • To operate this version of P300-IMX with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of P300-IMX with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate this version of P300-IMX with other Shure networked systems, reference the following list of minimum versions supported:
    • Designer 4.5.0
    • ANI22/ANI4IN/ANI4OUT 4.5.22
    • ANIUSB-MATRIX 4.5.23
    • MXA310 4.5.8
    • MXA910 4.5.8
    • MXA710 1.3.9
    • MXN5-C 1.3.8
    • MXA-MUTE 1.3.28
    • Microflex Wireless 9.0.4
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.9
4.4.13
February 23, 2021

New Feature

  • Call Status support – Changes LED state to notify the user when the room is in a call (off hook LEDS on) or out of a call (on hook LEDs off). This feature requires Logic and Call status enabled and connection to a supported USB codec. This setting is disabled by default.

Known Issues

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • P300 Shure Audio Encryption sometimes has crackling sound on audio
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 4.4.13 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX 4.4.13 with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate P300-IMX version 4.4.13 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.4.0
    • ANI22 4.4.8
    • ANIUSB-MATRIX 4.4.14
    • ANI4IN 4.4.8
    • ANI4OUT 4.4.8
    • MXA310 4.4.9
    • MXA710 1.2.1
    • MXA_MUTE 1.2.4
    • MXN5-C 1.2.1
    • MXA910 4.4.11
    • Microflex Wireless 8.0.3
    • Shure Update Utility 2.5.1
    • Shure Web Device Discovery 1.2.9
4.3.8
December 4, 2020

Bug Fix

  • Fixed an issue when using 8 channels of the P300 that would cause LED errors and the potential for audio artifacts

Known Issues

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier.

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 4.3.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX 4.3.8 with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate P300-IMX version 4.3.8 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.3
    • ANI22 4.3.7
    • ANIUSB-MATRIX 4.3.11
    • ANI4IN 4.3.7
    • ANI4OUT 4.3.7
    • MXA310 4.3.6
    • MXA710 1.1.5
    • MXA_MUTE 1.1.3
    • MXN5-C 1.1.1
    • MXA910 4.3.2
    • Microflex Wireless 8.0.3
    • Shure Update Utility 2.5.0
    • Shure Web Device Discovery 1.2.9
4.3.7
November 23, 2020

Improvements

  • USB Audio and Mute sync improvements
    • Improved performance with USB extending
    • Chrome OS Audio support
    • Mute sync improvements - Microsoft Teams, Zoom, and Skype for Business
    • Fixed an issue with Barco ClickShare CX50, where the P300 was recognized but does not pass audio
  • Bug Fixes

Known Issues

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements
  • P300s with firmware 4.3 require Designer versions 4.3 and higher and will NOT be supported in Designer versions 4.2.1 and earlier

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 4.3.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX 4.3.6 with Microsoft Teams, reference the following minimum versions:
    • Microsoft Teams Desktop: 1.3.00.24755
    • Microsoft Teams Rooms: 4.6.20.0
  • To operate P300-IMX version 4.3.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.3
    • ANI22 4.3.7
    • ANIUSB-MATRIX 4.3.11
    • ANI4IN 4.3.7
    • ANI4OUT 4.3.7
    • MXA310 4.3.6
    • MXA710 1.1.5
    • MXA_MUTE 1.1.3
    • MXN5-C 1.1.1
    • MXA910 4.3.2
    • Microflex Wireless 8.0.3
    • Shure Update Utility 2.5.0
    • Shure Web Device Discovery 1.2.9
4.2.7
October 30, 2020

Improvement

  • USB compatibility upgrade

Known Issues

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.2.X firmware to use this feature
  • Occasionally mute sync breaks between ANIUSB/P300 to MS Teams during a call when a mute button is quickly tapped multiple times. To resolve this, unplug and replug the USB cable or quit and restart Teams
  • USB Output audio may be distorted by the host PC when using some USB extenders
  • Shure Update Utility and Designer may not allow downgrading of new P300s shipped with 4.2.7 or higher due to a platform update to support future functionality and USB improvements

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.84.2.7with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.84.2.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.2
    • ANI22 4.2.18
    • ANIUSB-MATRIX 4.2.23
    • ANI4IN 4.2.18
    • ANI4OUT 4.2.18
    • MXA310 4.2.18
    • MXA710 1.0.5
    • MXA_MUTE 1.0.8
    • MXN5-C 1.0.6
    • MXA910 4.2.18
    • Microflex Wireless 8.0.3
    • Shure Update Utility 2.4.8
    • Shure Web Device Discovery 1.2.9
4.2.4
July 22, 2020

New Features

  • Designer
    • New Room Optimization for faster system configuration
    • Device Presets

Improvements

  • USB
    • Mute Sync improvements -– Zoom and Microsoft , Teams, and Skype for Business
    • Chrome OS audio support
  • Logic control

Known Issues

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.2.X firmware to use this feature
  • After unplugging the USB cable from a Chromebook during playback and then reconnecting, playback audio may be corrupted. To resolve this, power cycle the P300.
  • Occasionally mute sync breaks between ANIUSB/P300 to MS Teams during a call when a mute button is quickly tapped multiple times. To resolve this, unplug and replug the USB cable or quit and restart Teams.

Bug Fixes

  • Chrome OS USB audio distortion issues have been resolved
  • LED error fixed

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 4.2.4 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 4.2.4 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.2
    • ANI22 4.2.18
    • ANIUSB-MATRIX 4.2.19
    • ANI4IN 4.2.18
    • ANI4OUT 4.2.18
    • MXA310 4.2.18
    • MXA710 1.0.5
    • MXA_MUTE 1.0.8
    • MXN5-C 1.0.6
    • MXA910 4.2.18
    • Microflex Wireless 8.0.3
    • Shure Update Utility 2.4.8
    • Shure Web Device Discovery 1.2.9
4.1.11
February 11, 2020

New Features

  • Support for Dante Domain Manager
  • Dante Device Lock
  • Direct outputs from channels 1 – 8
  • Now has 8 Dante outputs (was 6)
  • Component user interfaces (web UIs) for the P300 and ANIUSB-MATRIX will be feature-reduced to support basic troubleshooting of network and device settings only. Designer version 3.2 will remain available for download to support legacy 3.1.x and 4.0.12 devices. 

    NOTE: Please ensure that field technicians and anyone providing in-field support on these devices downloads and installs the latest version of Designer. Device configuration and optimization capabilities will be minimal without Designer.

Improvements

  • Additional USB mute sync compatibility
  • Additional TPCI commands
  • For enhanced security, first-time user interface access will prompt the user to set up a passphrase. Users have the option of continuing without a passphrase, allowing for Shure Designer configuration software to securely configure the device within a location.
    • Passphrase length must be at least 8 characters up to a maximum of 64, all characters allowed
    • The passphrase may be disabled after the first login
    • Downgrade caution:
      • After the 4.1.37 upgrade, the device’s new passphrase (and/or its audio encryption passphrase) might exceed the allowed length of its prior firmware version. In that case, downgrading requires the following procedure to ensure passphrase compatibility:
        • Prior to downgrading, log in and disable the passphrase(s) or the change the passphrase(s) to the character length allowed by the prior firmware to be downgraded to.
        • Perform the firmware downgrade. Enable passphrase(s) as desired.
    • Using Designer software:
  • When multiple devices at different firmware levels are put into a location using Shure Designer software, the location passphrase for those devices must abide by the length and character set limitations of the older firmware. Advice: Update all devices in the location to the latest firmware in order to use a more robust passphrase.

Known Issue

  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature

Bug Fixes

  • Bug fixes

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 4.1.11 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 4.1.11 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 4.1
    • Shure SystemOn 3.2
    • ANI22 4.1.39
    • ANIUSB-MATRIX 4.1.39
    • ANI4IN 4.1.39
    • ANI4OUT 4.1.39
    • MXA310 4.1.37
    • MXA910 4.1.41
    • Microflex Wireless 8.0.3
    • Shure Update Utility 2.4.6
    • Shure Web Device Discovery 1.2.5
3.1.8
October 15, 2019

BUG FIXES

  • USB mute sync improvements
  • General bug fixes

NOTES

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.8 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANIUSB-MATRIX 3.1.6
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
3.1.6
June 12, 2019

Improvements

  • Support for logic functionality with MXA910 version 4.0.12 firmware

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.6 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.5
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
3.1.5
January 11, 2019

Improvements

  • Compatibility with Designer 3.1 System Configuration Software
  • Mute sync with Skype for Business (PC) and Zoom (PC and Mac)
  • Improved template values for Mic Input Gain, AGC Target, Automix settings, and Compressor Threshold for MXA310, MXA910, ANI4IN, MXW6, and MXW8
  • Improved initial USB speaker volume and sample rate settings
  • Improved Windows 7 media playback over USB
  • Hardware LED Metering and Clip Improvements
  • Bug fixes

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.5 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.5 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.5
    • MXA910 3.1.5
    • Microflex Wireless 6.0.3
    • Shure Update Utility 3.4.2
    • Shure Web Device Discovery 1.2.5
2.1.6
November 20, 2017

New Feature

  • Initial firmware for the P300 IntelliMix Audio Conferencing Processor

Notes

  • To operate P300-IMX version 2.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate P300-IMX version 2.1.6 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI22 2.0.11
    • ANIUSB-MATRIX 2.0.11
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA310 2.0.7
    • MXA910 2.0.16
    • Microflex Wireless 5.1.23
    • Shure Update Utility 2.4.1
    • Shure Web Device Discovery 1.1

Produits associés

IntelliMix P300

Le processeur audio de conférence P300 Intellimix intègre un DSP à la fois puissant et simple d'utilisation offrant une qualité audio irréprochable dans un appareil économique et sans soucis pour les applications de visioconférence.