Firmware

ANI22 - Audio Network Interface

Versions

Date postée

Téléchargement

6.0.41
February 29, 2024

Improvements

  • Enhancements to support Designer 6.0.0
  • Additional hardware support

Known Issues

  • Security Certificates:
    • Certificates must be in the PEM (Privacy Enhanced Mail) format
    • Certificates must be X.509 certificates and keys: PEM (Base64 ASCII), and DER (binary)
  • The CUI may become unresponsive after a firmware update
    • Workaround: Try clearing the cache on your browser to re-assert the connection.  Please check your web browser for instructions on how to clear the browser cache. A common method of clearing the cache of a browser is Ctrl SHIFT R .
  • Browser disconnection: Web browsers connected to our devices maybe disconnected after one hour if no user activity is detected.  Refresh the browser to re-establish the connection.
  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
  • ANI22-XLR reverses absolute phase from Analog in to Dante out – workaround is to enable “Invert polarity” for Dante Output
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

Notes

  • User Guide
  • Command Strings
  • To operate this version of ANI22 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • Updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI22 with other Shure networked systems, reference the following list of recommended versions supported:
    • ANI22/ANI4IN/ANI4OUT 6.0.41
    • ANIUSB 6.0.44
    • MXA310 6.0.23
    • MXA910 6.0.24
    • MXA920 6.0.38
    • MXA901 6.0.39
    • MXA902 6.0.32
    • MXW 10.0.X
    • ULXD4D/4Q 2.8.7
    • SCM820 1.4.3
    • Shure Update Utility 2.8.4
    • Shure Web Device Discovery 1.2.17
4.7.6
June 1, 2022

Improvements

  • Bug fixes

Known Issues

  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by a reboot
  • ANI22-XLR reverses absolute phase from Analog in to Dante out – workaround is to enable “Invert polarity” for Dante Output
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backward compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • To operate this version of ANI22 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • Updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI22 with other Shure networked systems, reference the following list of recommended versions supported:
    • ANI4IN 4.7.6
    • ANI4OUT 4.7.6
    • ANIUSB-MATRIX 4.7.16
    • MXA310 4.7.8
    • MXA910 4.7.13
    • Microflex Wireless 10.0.6
    • ULXD4D/4Q 2.6.3
    • SCM820 1.4.3
    • Shure Update Utility 2.7.1
    • Shure Web Device Discovery 1.2.17
4.6.6
November 5, 2021

Improvements

  • Bug fixes

Known Issues

  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • ANI22-XLR reverses absolute phase from Analog in to Dante out – workaround is to enable “Invert polarity” for Dante Output
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes

  • User Guide
  • Command Strings
  • This version of ANI22 is compatible with ANI22 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI22 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of ANI22 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 4.6.6
    • ANI4OUT 4.6.6
    • ANIUSB-MATRIX 4.6.7
    • MXA310 4.6.3
    • MXA910 4.6.6
    • Microflex Wireless 9.0.4
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.17
4.5.22
September 15, 2021

New Features 

  • Services – ability to configure network services

Improvements 

  • Bug fixes

Known Issues 

  • In AES67 mode - Audio does not pass after changing Dante Device name, followed by reboot
  • ANI22-XLR reverses absolute phase from Analog in to Dante out – workaround is to enable “Invert polarity” for Dante Output
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.3 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period.
    • Workaround: hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari)

Notes 

  • User Guide
  • Command Strings
  • This version of ANI22 is compatible with ANI22 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate this version of ANI22 with Dante Controller, reference the following minimum versions:
    • v3.10.2.4 (Windows)
    • v3.10.2.3 (macOS)
  • To operate this version of ANI22 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 4.5.22
    • ANI4OUT 4.5.22
    • ANIUSB-MATRIX 4.5.23
    • MXA310 4.5.8
    • MXA910 4.5.8
    • Microflex Wireless 9.0.4
    • ULXD4D/4Q 2.5.0
    • SCM820 1.4.3
    • Shure Update Utility 2.6.1
    • Shure Web Device Discovery 1.2.9
4.4.8
February 23, 2021

Improvements

  • Bug fixes

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature

Notes

  • User Guide
  • Command Strings
  • ANI22 version 4.4.8 is compatible with ANI22 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate ANI22 version 4.4.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate ANI22 version 4.4.8 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 4.4.8
    • ANI4OUT 4.4.8
    • ANIUSB-MATRIX 4.4.14
    • MXA310 4.4.9
    • MXA910 4.4.11
    • Microflex Wireless 8.0.3
    • ULXD4D/4Q 2.4.25
    • SCM820 1.3.3
    • Shure Update Utility 2.5.1
    • Shure Web Device Discovery 1.2.9
4.3.7
November 23, 2020

Improvements

  • Bug fixes

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature

Notes

  • User Guide
  • Command Strings
  • ANI22 version 4.3.7 is compatible with ANI22 devices running older firmware versions, but updating all devices used together to the same firmware version is recommended.
  • To operate ANI22 version 4.1.39 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate ANI22 version 4.3.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 4.3.7
    • ANI4OUT 4.3.7
    • ANIUSB-MATRIX 4.3.11
    • MXA310 4.3.6
    • MXA910 4.3.2
    • Microflex Wireless 8.0.3
    • ULXD4D/4Q 2.4.9
    • SCM820 1.3.3
    • Shure Update Utility 2.5.0
    • Shure Web Device Discovery 1.2.9
4.2.18
July 22, 2020

Improvement

  • Logic improvement

Bug Fixes

  • Removed Logic Inverter option. Fixed an issue where there was the potential for a loss of audio after a power cycle when using Static IP setting.
  • Failure to clear the encryption key when encryption is disabled

Known Issues

  • Factory reset occasionally fails to reset Dante settings and/or fully disable encryption. Solution: Reboot the device if unable to route audio after factory reset
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature

Notes

  • User Guide
  • Command Strings
  • ANI22 version 4.2.18 is compatible with ANI22 devices running version 4.2.18 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate ANI22 version 4.2.18 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate ANI22 version 4.2.18 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 4.2.18
    • ANI4OUT 4.2.18
    • ANIUSB-MATRIX 4.2.19
    • MXA310 4.2.18
    • MXA910 4.2.18
    • P300 4.2.4
    • Microflex Wireless 8.0.3
    • ULXD4D/4Q 2.4.9
    • SCM820 1.3.3
    • Shure Update Utility 2.4.8
    • Shure Web Device Discovery 1.2.9
4.1.39
February 11, 2020

New Features

  • Support for Dante Domain Manager
  • Support for Dante Device Lock
  • Support for AES67

Improvements

  • For enhanced security, first-time user interface access will prompt the user to set up a passphrase. Users have the option of continuing without a passphrase, allowing for Shure Designer configuration software to securely configure the device within a location.
    • Passphrase length must be at least 8 characters up to a maximum of 64, all characters allowed
    • The passphrase may be disabled after the first login
    • Downgrade caution:
      • After the 4.1.37 upgrade, the device’s new passphrase (and/or its audio encryption passphrase) might exceed the allowed length of its prior firmware version. In that case, downgrading requires the following procedure to ensure passphrase compatibility:
        • Prior to downgrading, log in and disable the passphrase(s) or the change the passphrase(s) to the character length allowed by the prior firmware to be downgraded to.
        • Perform the firmware downgrade. Enable passphrase(s) as desired.
    • Using Designer software:
  • When multiple devices at different firmware levels are put into a location using Shure Designer software, the location passphrase for those devices must abide by the length and character set limitations of the older firmware. Advice: Update all devices in the location to the latest firmware in order to use a more robust passphrase.

Bug Fixes

  • Fixed an issue where there was the potential for a loss of audio after a power cycle when using Static IP setting.

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Shure Audio Encryption is not backwards compatible; all devices must be on version 4.1 firmware to use this feature

Notes

  • User Guide
  • Command Strings
  • ANI22 version 4.1.39 is compatible with ANI22 devices running version 4.1.39 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate ANI22 version 4.1.39 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate ANI22 version 4.1.39 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 4.1.39
    • ANI4OUT 4.1.39
    • ANIUSB-MATRIX 4.1.39
    • MXA310 4.1.37
    • MXA910 4.1.41
    • Microflex Wireless 8.0.3
    • ULXD4D/4Q 2.4.9
    • SCM820 1.3.3
    • Shure Update Utility 2.4.6
    • Shure Web Device Discovery 1.2.5
2.0.18
December 18, 2017

Improvement

  • Reduces the loading time over VPN for the web-based graphical user interface (GUI)

Known Issue

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

Notes

  • User Guide
  • ANI22 version 2.0.18 is compatible with ANI22 devices running version 2.0.18 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate ANI22 version 2.0.18 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate ANI22 version 2.0.18 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 2.0.19
    • MXA310 2.0.19
    • MXA910 2.0.19
    • Microflex Wireless 5.1.26
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.4.1
    • Shure Web Device Discovery 1.1
2.0.11
August 31, 2017

New Features

  • Initial firmware for ANI22

Notes

  • To operate ANI22 version 2.0.11 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate ANI22 version 2.0.11 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA310 2.0.7
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23
    • SCM820 1.3.3
    • Shure Update Utility 2.4
    • Shure Web Device Discovery 1.1

Produits associés

ANI22

L'interface ANI22 peut récupérer ou transmettre deux signaux Micro/Ligne via un réseau Dante pour faciliter le routage audio et le contrôle à distance via l'application web.