Downloads

Firmware Archives

Title
Associated Products
File Size
August 27, 2019
MXCW640 - Wireless Conference Unit
2.0.9

These release notes cover the following models:

  • MXCWAPT Access Point Receiver
  • MXCW640 Wireless Conference Unit
  • MXCWNCS Networked Charging Station

 

IMPROVEMENT

  • Fixed a bug on the MXCWAPT where seat number-based TPCI commands fail to provide property updates after the APT is rebooted in manual registration mode

 

KNOWN ISSUES

MXCWAPT

  • Mute Concealment is not implemented in the interpretation channels. This feature will be available in the next release.

 

MXCWAPT Component GUI

  • General note: Clear browser cache (Shift+control+F5 on Windows) after the firmware update is done if you are already in the GUI at the time of the update.
  • Browser refresh may be required in the following situations:
    • On a Static/DHCP IP configuration change
    • If MXCW640s lose sync with GUI during registration, deregistration, or reboot
    • If GUI intermittently incorrectly shows some MXCW640s remained offline
  • There’s an intermittent issue where voting results are shown in the Display View even if the display icon is enabled through the Chairman View. Users may need to refresh their browser to resolve.
  • During some system factory resets, the APT’s reset initiation may be delayed ~2 minutes, in comparison to the MXCW640s.
  • Pinned seat numbers are not cleared after APT reboot in Auto+Open Connection Mode.
  • APT Help topics are not available in Thai, Turkish, and Lithuanian.
  • Some translated text is misaligned or may have extra, unnecessary punctuation or text.
  • Component GUIs take longer to load in Internet Explorer than Google Chrome, especially if used in a large system.

 

MXCW640

  • Some languages experience text issues.
  • Some text is not translated.

 

MXCWNCS

Users may need to refresh their browser on a Static/DHCP IP configuration change.

APT Help topics are not available in Thai, Turkish, and Lithuanian.

 

NOTES

  • User Guide
  • To use MXCW version 2.0.9 with other Shure software, reference the following list of minimum versions:
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
    • Shure NFC Programming Application 1.0.3
August 27, 2019
MXCWAPT - Access Point
2.0.9

These release notes cover the following models:

  • MXCWAPT Access Point Receiver
  • MXCW640 Wireless Conference Unit
  • MXCWNCS Networked Charging Station

 

IMPROVEMENT

  • Fixed a bug on the MXCWAPT where seat number-based TPCI commands fail to provide property updates after the APT is rebooted in manual registration mode

 

KNOWN ISSUES

MXCWAPT

  • Mute Concealment is not implemented in the interpretation channels. This feature will be available in the next release.

 

MXCWAPT Component GUI

  • General note: Clear browser cache (Shift+control+F5 on Windows) after the firmware update is done if you are already in the GUI at the time of the update.
  • Browser refresh may be required in the following situations:
    • On a Static/DHCP IP configuration change
    • If MXCW640s lose sync with GUI during registration, deregistration, or reboot
    • If GUI intermittently incorrectly shows some MXCW640s remained offline
  • There’s an intermittent issue where voting results are shown in the Display View even if the display icon is enabled through the Chairman View. Users may need to refresh their browser to resolve.
  • During some system factory resets, the APT’s reset initiation may be delayed ~2 minutes, in comparison to the MXCW640s.
  • Pinned seat numbers are not cleared after APT reboot in Auto+Open Connection Mode.
  • APT Help topics are not available in Thai, Turkish, and Lithuanian.
  • Some translated text is misaligned or may have extra, unnecessary punctuation or text.
  • Component GUIs take longer to load in Internet Explorer than Google Chrome, especially if used in a large system.

 

MXCW640

  • Some languages experience text issues.
  • Some text is not translated.

 

MXCWNCS

Users may need to refresh their browser on a Static/DHCP IP configuration change.

APT Help topics are not available in Thai, Turkish, and Lithuanian.

 

NOTES

  • User Guide
  • To use MXCW version 2.0.9 with other Shure software, reference the following list of minimum versions:
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
    • Shure NFC Programming Application 1.0.3
August 27, 2019
MXCWNCS - Networked Charging Station
2.0.9

These release notes cover the following models:

  • MXCWAPT Access Point Receiver
  • MXCW640 Wireless Conference Unit
  • MXCWNCS Networked Charging Station

 

IMPROVEMENT

  • Fixed a bug on the MXCWAPT where seat number-based TPCI commands fail to provide property updates after the APT is rebooted in manual registration mode

 

KNOWN ISSUES

MXCWAPT

  • Mute Concealment is not implemented in the interpretation channels. This feature will be available in the next release.

 

MXCWAPT Component GUI

  • General note: Clear browser cache (Shift+control+F5 on Windows) after the firmware update is done if you are already in the GUI at the time of the update.
  • Browser refresh may be required in the following situations:
    • On a Static/DHCP IP configuration change
    • If MXCW640s lose sync with GUI during registration, deregistration, or reboot
    • If GUI intermittently incorrectly shows some MXCW640s remained offline
  • There’s an intermittent issue where voting results are shown in the Display View even if the display icon is enabled through the Chairman View. Users may need to refresh their browser to resolve.
  • During some system factory resets, the APT’s reset initiation may be delayed ~2 minutes, in comparison to the MXCW640s.
  • Pinned seat numbers are not cleared after APT reboot in Auto+Open Connection Mode.
  • APT Help topics are not available in Thai, Turkish, and Lithuanian.
  • Some translated text is misaligned or may have extra, unnecessary punctuation or text.
  • Component GUIs take longer to load in Internet Explorer than Google Chrome, especially if used in a large system.

 

MXCW640

  • Some languages experience text issues.
  • Some text is not translated.

 

MXCWNCS

Users may need to refresh their browser on a Static/DHCP IP configuration change.

APT Help topics are not available in Thai, Turkish, and Lithuanian.

 

NOTES

  • User Guide
  • To use MXCW version 2.0.9 with other Shure software, reference the following list of minimum versions:
    • Shure Update Utility 2.4.5
    • Shure Web Device Discovery 1.2.5
    • Shure NFC Programming Application 1.0.3
August 15, 2019
Microflex Complete
8.5.0

Release notes cover the following models:

  • MXC615
  • MXC620/620-F
  • MXC630/630-F
  • MXC640
  • MXCIC
  • MXCMIU
  • MXCSIGN

Important

  • This firmware release can be used to update Microflex Complete (MXC), DCS 6000, or DCS 5900 systems using DIS CCU, CU 5905, CU 6105, or CU 6110 Central Units.
  • Systems using CU 6000, CU 6005, CU 6010 and CU 6011 Central Units are not supported in this release.
  • Firmware Upgrade Utility (FUU) v1684, which is included in the release, is required to update MXC devices. In the FUU, MXC devices will be designated with an "-A" suffix.

New Features

DIS-CCU (6000 Mode)

  • Support for Dual delegate role
  • Real-time diagnostics for MXC units:
    • Loop problem (due to cable or unit failure)
    • Unit offline/online status
    • Low voltage level
    • Alerts appear in the event log
  • DCS-LAN network topology information for MXC units
  • Activation of LED indication for units in chain and in loop
  • Save and restore CCU settings
  • TPCI commands showing when interpreter audio is present on interpreter channels

MXCMIU

  • Support for Dual Delegate role when used with two MXCMIU-FL/FS front plates connected to the HDMI A and B connectors (supports dual microphones, dual loudspeakers, dual LEDs)

MXC615

  • Support for Dual Delegate role

MXC620

  • Support for Dual Delegate role (except NFC ID card functionality)

MXC640

  • Support for Dual Delegate role (except NFC ID card functionality)
  • Participant speech timer appears on MXC640 screen when used with SW6000 software
  • Ability in SW6000 software to allow all participants with a specific role (e.g. Delegate) to view or hide the speak/request list on their MXC640 screen
  • Chairman can start/stop meetings on MXC640 (meetings must be set up in SW6000 software)
  • Support for 2-button (Yes/No) voting in standalone mode without SW6000 software
  • Ability to upload startup screen image/logo via Firmware Update Utility
  • Support for up to 1000 agenda items
  • 3 additional screen languages (Thai, Turkish, Lithuanian added; brings total to 17)

MXCIC

  • Interpreter can view the Speak/Request list on MXCIC screen (when used standalone or with SW6000)
  • "Slow" button now active
  • Language Pre-select control behavior changed: Language selection is now activated on release of a pre-select button, in addition to clicking the rotary button to confirm. Also, pressing or turning the rotary button while holding a pre-select button launches the pre-select language list.

Improvements

MXC640

  • Improvements to result note display
  • All language-based properties at meeting end
  • Info in the top menu is updated

Bug Fixes

DIS-CCU

  • Corrected a bug where seat numbers were not sorted in the Participant Setup page

MXC640

  • Corrected bugs where
    • it was not possible to set a subject active
    • the Speak button LED does not blink when unit is next in the request list in FIFO mode
    • the unit language is not changed back to system language after the user is logged out or after stopping the meeting

Known Issues

  • When the system uses SW6000, voting result labels in TCP/IP control strings are shifted.
  • During boot up, there may be a spike on the analog output.
  • Some units in systems >150 units may not be shown in the Topology report.
  • Some units may reset when cable breaks in a loop on an EX 6010 unit.
  • The Event log in DIS-CCU CGUI does not work when SW6000 is connected and a meeting is started.
  • MXC640
    • When an agenda with max. items and with max. words in the item name and descriptions is received, the GUI may not be responsive for a period of time
    • Manually entered voting results are not shown if a normal voting session has not been started first
    • The agenda subject name for a manually entered result may be wrong
    • It is not possible to use an MXC640 configured as dual delegate with SW6000 if the use of NFC cards is enabled
    • Re-doing an attendance check might make the attendance button nonoperational
    • The percent indication in the Voting Result screen may not be correct for user-specified voting configurations
  • MXCMIU
    • The Exclusive button does not work if configured to the function button (left button)

Notes

  • MXC and DCS 6000 firmware files are packaged together in the same release file.
  • To operate MXC devices with release version 8.5.0 with other Shure networked systems, see the following list of minimum software and firmware versions:
    • DCS 6000 8.5.0
    • SW6000 6.8.33a
    • Shure NFC Programming App 1.0.3
July 15, 2019
MV88+ Video Kit - Digital Stereo Condenser Microphone
1.0.19

IMPROVEMENTS

  • Fixed an issue that could cause the MV88+ to crash
  • Fixed an issue where the microphone LED would intermittently flash an amber light
  • Fixed an issue for iOS users where the mic would occasionally not be recognized by the device when plugged in

Known Issues

  • Users with some Android devices may experience 9 millisecond audio drop-outs when recording with the MV88+
  • In a small number of instances, unplugging the MV88+ from an iPhone XS, XS Max, or XR can cause the phone to crash and reboot. This is due to an Apple bug that is being investigated and should be resolved in an upcoming iOS release
  • When connected to iPad Pro via a USB-C cable, the MV88+ will pass audio and gain can be adjusted. However the MOTIV apps will only display ‘external mic’, and the settings screen will not be available. Shure recommends using another device to configure the settings before using with iPad Pro. No adjustments can be made in real time (except gain) on the Shure MOTIV apps when using an iPad Pro.

Notes

June 27, 2019
ANIUSB-MATRIX - Audio Network Interface
3.1.6

Recommendation

Update all Audio Network Interfaces in a configuration to the newest firmware versions.

Improvement

  • Fix for web server performance issues

Known Issues

  • There is the potential for a loss of audio after a power cycle when using Static IP setting: Un-checking and re-checking the Dante connections is necessary to reestablish audio between devices. An Alternative fix is to use DHCP addressing.
  • TCPI set 0 for input level switch also incorrectly changes the output level switch and vice versa.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported.
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).

Notes

  • User Guide
  • Command Strings
  • ANIUSB-MATRIX version 3.1.6 is compatible with ANIUSB-MATRIX devices running version 3.1.6 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate ANIUSB-MATRIX version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate ANIUSB-MATRIX version 3.1.6 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • P300 3.1.6
    • ULXD4D/4Q 2.3.34
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
June 27, 2019
MXA310 - Microflex Advance Table Array Microphone
3.1.6

Recommendation

Update all Audio Network Interfaces in a configuration to the newest firmware versions.

Improvement

  • Fix for web server performance issues

Known Issues

  • After updating from version 2.X to 3.1.6, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > Response Actual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC > LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL > LOGIC
< REP MUTE_BUTTON OFF > DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.6 is compatible with MXA310 devices running version 3.1.6 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.6 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.6
    • ULXD4D/4Q 2.3.34
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
June 27, 2019
MXA310 - Microflex Advance Table Array Microphone (Dante Only)
3.1.6

Recommendation

Update all Audio Network Interfaces in a configuration to the newest firmware versions.

Improvement

  • Fix for web server performance issues

Known Issues

  • After updating from version 2.X to 3.1.6, Channel EQ settings return to their default settings.
  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 3.1 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).
  • The Mute Control Function command string response is incorrect when using <GET 0 ALL>
    • When using < GET MUTE_CONTROL_FUNC >, the response is as documented.
    • When using < GET 0 ALL >, the response should be mapped as follows:
< GET 0 ALL > Response Actual MUTE_CONTROL_FUNC
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOGIC > LOCAL
< REP MUTE_BUTTON ON > ... < REP MUTE_CONTROL_FUNC LOCAL > LOGIC
< REP MUTE_BUTTON OFF > DISABLED

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • MXA310 version 3.1.6 is compatible with MXA310 devices running version 3.1.6 and below, but updating all devices used together to the same firmware version is recommended.
  • To operate MXA310 version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 3.1.6 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.6
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.6
    • ULXD4D/4Q 2.3.34
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
June 12, 2019
MXA910 - Microflex Advance Ceiling Array Microphone
4.0.12

Recommendation

Update all MXA910 devices in a configuration to the same firmware version. Devices on version 4.0.12 cannot be downgraded to previous versions.

Improvements

  • Incorporates IntelliMix® DSP including AEC, Noise Reduction, Automatic mixing, AGC, Compressor, Delay and EQ. IntelliMix® uses Shure’s patent-pending acoustic echo cancellation technology to deliver a single channel of auto-mixed, noise- and echo-free audio.
  • Patent-pending Autofocus™ technology continually fine-tunes the position of each lobe in real time, for consistent sound when participants lean back in their chairs, or even stand up.

Known Issues

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • When attempting to load the device’s web page after using SUU to upgrade or downgrade between MXA 4.0 and earlier releases, the browser may appear to be stuck on the “Loading” screen with the progress bar continually moving. This will typically happen if two upgrades or downgrades are performed within a one-hour period. To correct this, hold your Shift key and click the Refresh button in your browser (or press Ctrl+Shift+R [Win]/Ctrl+F5 [Win]/Cmd+Shift+R [Mac]; note the keyboard shortcut doesn't work on Safari).

Notes

  • User Guide
  • New Demo Web UI
  • Command Strings
  • To operate MXA910 version 4.0.12 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA910 version 4.0.12 with Shure software or other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • MXA310 3.1.5
    • Microflex Wireless 6.0.3
    • P300 IntelliMix® Audio Conferencing Processor 3.1.6
    • ULXD4D/4Q 2.3.21
    • SCM820 1.3.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5
June 12, 2019
P300-IMX IntelliMix Audio Conferencing Processor
3.1.6

Improvements

  • Support for logic functionality with MXA910 version 4.0.12 firmware

Notes

  • User Guide
  • Command Strings
  • To operate P300-IMX version 3.1.6 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (macOS)
  • To operate P300-IMX version 3.1.6 with other Shure networked systems, reference the following list of minimum versions supported:
    • Shure Designer 3.2
    • Shure SystemOn 3.2
    • ANI22 2.0.18
    • ANIUSB-MATRIX 3.1.5
    • ANI4IN 2.0.18
    • ANI4OUT 2.0.18
    • MXA310 3.1.5
    • MXA910 4.0.12
    • Microflex Wireless 6.0.3
    • Shure Update Utility 2.4.4
    • Shure Web Device Discovery 1.2.5