Downloads

Software & Firmware Archives

Filter by update type

Type

Release Title

Latest Version

Associated Products

Download

Firmware
2.5.0
July 1, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version. 

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q: 
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • If your ULXD4D/Q is on version 1.3.6 or older, first upgrade to version 1.4.8 before upgrading to the latest version of ULX-D. Because version 1.4.8 is no longer available on Shure Update Utility, you will need to download the firmware from Shure's Firmware Archive. Follow these steps:
    1. Download Shure Update Utility
    2. Download ULXD4D version 1.4.8 or ULXD4Q version 1.4.8 to your computer and copy the .pack file to Documents > Shure > Firmware
    3. Launch Shure Update Utility, connect your devices to your computer, and follow SUU instructions on uploading new firmware to devices.
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    1. Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    2. Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    3. Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0
July 1, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • If your ULXD4D/Q is on version 1.3.6 or older, first upgrade to version 1.4.8 before upgrading to the latest version of ULX-D. Because version 1.4.8 is no longer available on Shure Update Utility, you will need to download the firmware from Shure's Firmware Archive. Follow these steps:
    1. Download Shure Update Utility
    2. Download ULXD4D version 1.4.8 or ULXD4Q version 1.4.8 to your computer and copy the .pack file to Documents > Shure > Firmware
    3. Launch Shure Update Utility, connect your devices to your computer, and follow SUU instructions on uploading new firmware to devices.
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    1. Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    2. Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    3. Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.5.0
July 1, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • NEW TCPI commands for ULXD4/ULXD4D/ULXD4Q:
    • MODEL - Name of the receiver model
    • TX_FW - Firmware version of the received transmitter
  • Support added for new ULXD4D/Q devices which ensure that encryption is used
    • At this time, AXT600 Spectrum Manager does not support always encryption DCID

Notes

  • User Guide
  • If your ULXD4D/Q is on version 1.3.6 or older, first upgrade to version 1.4.8 before upgrading to the latest version of ULX-D. Because version 1.4.8 is no longer available on Shure Update Utility, you will need to download the firmware from Shure's Firmware Archive. Follow these steps:
    1. Download Shure Update Utility
    2. Download ULXD4D version 1.4.8 or ULXD4Q version 1.4.8 to your computer and copy the .pack file to Documents > Shure > Firmware
    3. Launch Shure Update Utility, connect your devices to your computer, and follow SUU instructions on uploading new firmware to devices.
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    1. Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    2. Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    3. Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D version 2.5.0 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.5.0
    • SBC250/450/850 Networked Charging Stations 2.4.13
    • Axient AXT600 Spectrum Manager 2.1.38
    • Wireless Workbench 6.14.1
    • Shure Update Utility 2.6.1
    • ShurePlus Channels 1.4.6
Firmware
2.4.25
February 17, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Changed the default RF band from AB to JB for ULXD4=-AB receivers
  • Add support for China 470 MHz – 510 MHz frequency band (G53)

Notes

  • User Guide
  • If your ULXD4D/Q is on version 1.3.6 or older, first upgrade to version 1.4.8 before upgrading to the latest version of ULX-D. Because version 1.4.8 is no longer available on Shure Update Utility, you will need to download the firmware from Shure's Firmware Archive. Follow these steps:
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    • Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    • Align the infrared ports with the transmitter
    • Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    • Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    • Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    • Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D version 2.3.25 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.25
    • SBC250/450/850 Networked Charging Stations 2.4.9
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • PSM1000 1.7.10
    • Axient AXT600 Spectrum Manager 2.1.31
    • Wireless Workbench 6.14.0
    • Shure Update Utility 2.5.1
    • ShurePlus Channels 1.4.5
Firmware
2.4.25
February 17, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Changed the default RF band from AB to JB for ULXD4=-AB receivers
  • Add support for China 470 MHz – 510 MHz frequency band (G53)

Notes

  • User Guide
  • If your ULXD4D/Q is on version 1.3.6 or older, first upgrade to version 1.4.8 before upgrading to the latest version of ULX-D. Because version 1.4.8 is no longer available on Shure Update Utility, you will need to download the firmware from Shure's Firmware Archive. Follow these steps:
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    • Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    • Align the infrared ports with the transmitter
    • Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    • Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    • Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    • Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D version 2.3.25 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.25
    • SBC250/450/850 Networked Charging Stations 2.4.9
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • PSM1000 1.7.10
    • Axient AXT600 Spectrum Manager 2.1.31
    • Wireless Workbench 6.14.0
    • Shure Update Utility 2.5.1
    • ShurePlus Channels 1.4.5
Firmware
2.4.25
February 17, 2021 View All Updates

Important

  • ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvements

  • Changed the default RF band from AB to JB for ULXD4=-AB receivers
  • Add support for China 470 MHz – 510 MHz frequency band (G53)

Notes

  • User Guide
  • If your ULXD4D/Q is on version 1.3.6 or older, first upgrade to version 1.4.8 before upgrading to the latest version of ULX-D. Because version 1.4.8 is no longer available on Shure Update Utility, you will need to download the firmware from Shure's Firmware Archive. Follow these steps:
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    • Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    • Align the infrared ports with the transmitter
    • Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    • Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    • Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    • Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D version 2.3.25 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.25
    • SBC250/450/850 Networked Charging Stations 2.4.9
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.24
    • PSM1000 1.7.10
    • Axient AXT600 Spectrum Manager 2.1.31
    • Wireless Workbench 6.14.0
    • Shure Update Utility 2.5.1
    • ShurePlus Channels 1.4.5
Firmware
2.4.9
November 11, 2019 View All Updates

New Features

  • Dante ™ update to software version 4.2.1.1 and firmware version 4.0.2.9

Improvements

  • The lock setting for the front panel SCAN button now prevents frequency changes due to group scans initiated by other ULXD4 units
  • Support for additional RF bands:
    • Thailand 694 – 703 MHz frequency band (M19)
    • Thailand 748 – 758 MHz frequency band (Q12)
  • Bug fixes

Notes

  • User Guide
  • To operate ULX-D version 2.4.9 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.4.9
    • SBC250/450/850 Networked Charging Stations 2.3.6
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
    • PSM1000 1.6.21
    • Axient AXT600 Spectrum Manager 2.1.22
    • Wireless Workbench 6.13.1
    • Shure Update Utility 2.4.6
    • ShurePlus Channels 1.4.2
Firmware
2.4.9
November 11, 2019 View All Updates

New Features

  • Dante ™ update to software version 4.2.1.1 and firmware version 4.0.2.9

Improvements

  • The lock setting for the front panel SCAN button now prevents frequency changes due to group scans initiated by other ULXD4 units
  • Support for additional RF bands:
    • Thailand 694 – 703 MHz frequency band (M19)
    • Thailand 748 – 758 MHz frequency band (Q12)
  • Bug fixes

Notes

  • User Guide
  • To operate ULX-D version 2.4.9 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.4.9
    • SBC250/450/850 Networked Charging Stations 2.3.6
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
    • PSM1000 1.6.21
    • Axient AXT600 Spectrum Manager 2.1.22
    • Wireless Workbench 6.13.1
    • Shure Update Utility 2.4.6
    • ShurePlus Channels 1.4.2
Firmware
2.4.9
November 11, 2019 View All Updates

New Features

  • Dante ™ update to software version 4.2.1.1 and firmware version 4.0.2.9

Improvements

  • The lock setting for the front panel SCAN button now prevents frequency changes due to group scans initiated by other ULXD4 units
  • Support for additional RF bands:
    • Thailand 694 – 703 MHz frequency band (M19)
    • Thailand 748 – 758 MHz frequency band (Q12)
  • Bug fixes

Notes

  • User Guide
  • To operate ULX-D version 2.4.9 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.4.9
    • SBC250/450/850 Networked Charging Stations 2.3.6
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
    • PSM1000 1.6.21
    • Axient AXT600 Spectrum Manager 2.1.22
    • Wireless Workbench 6.13.1
    • Shure Update Utility 2.4.6
    • ShurePlus Channels 1.4.2
Firmware
2.3.34
May 10, 2019 View All Updates

Important

  • New hardware revisions with the ULX-D 2.3.34 firmware version cannot be downgraded to previous firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

Improvement

  • Updated the firmware version number for the purpose of keeping all ULX-D firmware version numbers aligned for brand-new system installations.

Notes

  • User Guide
  • If your ULXD4D/Q is on version 1.3.6 or older, first upgrade to version 1.4.8 before upgrading to the latest version of ULX-D. Because version 1.4.8 is no longer available on Shure Update Utility, you will need to download the firmware from Shure's Firmware Archive. Follow these steps:
    1. Download Shure Update Utility
    2. Download ULXD4D version 1.4.8 or ULXD4Q version 1.4.8 to your computer and copy the .pack file to Documents > Shure > Firmware
    3. Launch Shure Update Utility, connect your devices to your computer, and follow SUU instructions on uploading new firmware to devices.
  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, updates from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    1. Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    2. Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    3. Update receiver to 1.6.6 or later.
  • To operate ULX-D version 2.3.34 devices with other Shure networked systems and software, see the following list of minimum versions:
    • ULX-D ULXD1/2/6/8 Transmitters and ULXD4/4D/4Q Receivers 2.3.34
    • SBC250/450/850 Networked Charging Stations 2.3.6
    • QLX-D QLXD1/2 Transmitters and QLXD4 Receivers 2.3.8
    • PSM1000 1.6.21
    • Axient AXT600 Spectrum Manager 2.1.22
    • Wireless Workbench 6.12.6
    • Shure Update Utility 2.4.4
    • ShurePlus Channels 1.4.2