GLXD Firmware update failed

FAQ #4964 Updated October 11, 2018

Question:

GLXD Firmware update failed

Answer:

It is possible that the firmware update for a GLXD transmitter or receiver can fail due to a "corrupt device." The process listed below should resolve this.

Example error message:

"Failed to install primary firmware 2.0.0.1 to GLX-RXPedal-54134036-WRU Device is on golden FPGA, please call support"

Image

To correct this issue you will need to:

  1. Connect GLXD component to computer via USB
  2. Power off GLXD component (if not already off)
  3. Open Shure Update Utility
  4. Hold down link button and turn GLXD component on.
  5. Unit reboots
  6. Update utility will then recognize GLXD as a corrupt device and give you the option to repair it:
    Image
  7. Click on repair corrupt device button
  8. Shure Update Utility will recognize the GLXD unit
    Image
  9. Select the GLXD component and perform update again

Attachments