• Page 1 of 30
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
  6. 6
  7. 30
Filter by: Date Posted Filter by: Title Filter by: Version Associated Products Filter by: File Size
July 07, 2017 ANI4IN - Audio Network Interface 2.0.7 See release notes Download PACK (3.61 mb)

RECOMMENDATION

Update all ANI4IN devices in a configuration to the same firmware version.

NEW FEATURES

  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ copy/paste and import/export options

IMPROVEMENTS

  • Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
  • Configuration
    • PEQ tab added  
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset" 
  • Device names can now begin with a number
  • New commands strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

KNOWN ISSUE

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

NOTES

  • ANI4IN: User Guide Command Strings
  • ANI4IN version 2.0.7 is compatible with ANI4IN devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate ANI4IN version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate ANI4IN version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23 
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1
July 07, 2017 ANI4OUT - Audio Network Interface 2.0.8 See release notes Download PACK (3.37 mb)

RECOMMENDATION

Update all ANI4OUT devices in a configuration to the same firmware version.

NEW FEATURES

  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ copy/paste and import/export options

IMPROVEMENTS

  • Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
  • Configuration
    • PEQ tab added  
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset" 
  • Device names can now begin with a number
  • New commands strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

KNOWN ISSUE

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

NOTES

  • ANI4OUT: User Guide | Command Strings
  • ANI4OUT version 2.0.8 is compatible with ANI4OUT devices running version 2.0.8 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate ANI4OUT version 2.0.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate ANI4OUT version 2.0.8 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23 
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1

 

July 07, 2017 MXA310 - Microflex Advance Table Array Microphone 2.0.7 See release notes Download PACK (4.02 mb)

RECOMMENDATION

Update all MXA310 microphones in a configuration to the same firmware version.

NEW FEATURES

  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ import/export options

IMPROVEMENTS

  • Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
  • Configuration
    • "Add/Remove Channel" button added on Coverage tab
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset" 
  • Device names can now begin with a number
  • New command strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

KNOWN ISSUES

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Encryption may become disabled in an extremely rare case after a power cycle of the device; users must re-enable encryption in the UI if this occurs.
  • If Channel 1 is removed using the Add/Remove Channel feature and Channel 2, 3, or 4 is left as a single channel, then audio will not pass through the Automix Out channel. Channel 1 is the only channel that passes audio through the Automix Out channel.

NOTES

  • MXA310: User Guide | Command strings
  • MXA310 version 2.0.7 is compatible with MXA310 devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate MXA310 version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23 
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1
July 07, 2017 MXA910 - Microflex Advance Ceiling Array Microphone 2.0.8 See release notes Download PACK (16.3 mb)

RECOMMENDATION

Update all MXA910 microphones in a configuration to the same firmware version.

NEW FEATURES

  • AES67
  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ copy/paste and import/export options

IMPROVEMENTS

  • Configuration
    • PEQ tab added  
    • Revised templates for better out-of-the-box room coverage
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset" 
  • Improved auto position performance
  • Device names can now begin with a number
  • New commands strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

KNOWN ISSUE

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

NOTES

  • MXA910: User Guide | Command Strings
  • MXA910 version 2.0.8 is compatible with MXA910 devices running version 2.0.8 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate MXA910 version 2.0.8 with Dante™ Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA910 version 2.0.8 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA310 2.0.8
    • Microflex Wireless 5.1.23 
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1
June 30, 2017 ANI4IN - Audio Network Interface (Dante Only) 2.0.7 See release notes Download PACK (3.35 mb)

RECOMMENDATION

Update all ANI4IN devices in a configuration to the same firmware version.

NEW FEATURES

  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ copy/paste and import/export options

IMPROVEMENTS

  • Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
  • Configuration
    • PEQ tab added  
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset" 
  • Device names can now begin with a number
  • New commands strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

KNOWN ISSUE

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

NOTES

  • ANI4IN: User Guide Command Strings
  • ANI4IN version 2.0.7 is compatible with ANI4IN devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate ANI4IN version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate ANI4IN version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23 
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1
June 30, 2017 ANI4OUT - Audio Network Interface (Dante Only) 2.0.8 See release notes Download PACK (3.1 mb)

RECOMMENDATION

Update all ANI4OUT devices in a configuration to the same firmware version.

NEW FEATURES

  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ copy/paste and import/export options

IMPROVEMENTS

  • Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
  • Configuration
    • PEQ tab added  
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset" 
  • Device names can now begin with a number
  • New commands strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

KNOWN ISSUE

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported

NOTES

  • ANI4OUT: User GuideCommand Strings
  • ANI4OUT version 2.0.8 is compatible with ANI4OUT devices running version 2.0.8 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate ANI4OUT version 2.0.8 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate ANI4OUT version 2.0.8 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23 
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1

 

June 30, 2017 MXA310 - Microflex Advance Table Array Microphone (Dante Only) 2.0.7 See release notes Download PACK (3.75 mb)

RECOMMENDATION

Update all MXA310 microphones in a configuration to the same firmware version.

NEW FEATURES

  • Audio Encryption support with MXA910, MXA310, ANI4IN, ANI4OUT, ANIUSB-MATRIX, ANI22 and P300-IMX.
  • Packet Bridge
  • PEQ import/export options

IMPROVEMENTS

  • Integrates Audinate's Dante™ Ultimo firmware update, which resolves a rare audio loss issue that can occur when devices are static for longer than 1 month.
  • Configuration
    • "Add/Remove Channel" button added on Coverage tab
  • Presets
    • "Default Settings" added as a preset
    • Name of the active preset displays above the Preset drop-down
    • "Clear Preset" option added to "Save As Preset" 
  • Device names can now begin with a number
  • New command strings
  • Fixed an IP configuration issue in manual mode that prevents setting IP address w.x.y.z with subnet mask 255.0.0.0 for class A networks.
  • General bug fixes

KNOWN ISSUES

  • When exporting Presets using Safari on a Mac OS, the file type is saved incorrectly and must be renamed to .json to be imported
  • Encryption may become disabled in an extremely rare case after a power cycle of the device; users must re-enable encryption in the UI if this occurs.
  • If Channel 1 is removed using the Add/Remove Channel feature and Channel 2, 3, or 4 is left as a single channel, then audio will not pass through the Automix Out channel. Channel 1 is the only channel that passes audio through the Automix Out channel.

NOTES

  • MXA310: User Guide | Command strings
  • MXA310 version 2.0.7 is compatible with MXA310 devices running version 2.0.7 and below, but it is recommended to update all devices used together to the same firmware version.
  • To operate MXA310 version 2.0.7 with Dante Controller, reference the following minimum versions: v3.10.2.4 (Windows) and v3.10.2.3 (Mac OS X)
  • To operate MXA310 version 2.0.7 with other Shure networked systems, reference the following list of minimum versions supported:
    • ANI4IN 2.0.7
    • ANI4OUT 2.0.8
    • MXA910 2.0.8
    • Microflex Wireless 5.1.23 
    • ULXD4D/4Q 2.1.16
    • SCM820 1.3.3
    • Shure Update Utility 2.3.0.18
    • Shure Web Device Discovery 1.1
June 22, 2017 SBRC - Shure Battery Rack Charger 1.0.1 See release notes Download PACK (483 kb)

NEW FEATURE

Initial release

NOTES

May 19, 2017 ULXD1/2 - Wireless Transmitter 2.1.16 See release notes Download PACK (200 kb)

IMPORTANT

ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

IMPROVEMENTS

  • Compatibility with new products:
    • ULXD6 Wireless Boundary Microphone Transmitter
    • ULXD8 Wireless Gooseneck Base Transmitter
    • SBC450 4-Bay Networked Charging Station 
    • SBC850 8-Bay Networked Charging Station
  • New TPCI commands for charging stations, receivers, and transmitters
  • Bug fixes
    • Custom groups for AB/JB bands now correctly transfer via IR sync
    • Antenna power alert will persist until it is cleared
    • Fixed a sporadic issue of transmitter firmware updates failing

KNOWN ISSUE

  • ULX-D version 2.1.16 is not compatible with SystemOn 2.1

NOTES

  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    • Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    • Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    • Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D devices on version 2.1.16 with other Shure networked systems and software, see the following list of minimum software versions:

 

May 19, 2017 ULXD1/2 - Extended Bands Wireless Transmitter 2.1.16 See release notes Download PACK (273 kb)

IMPORTANT

ULX-D 2.X firmware versions are incompatible with ULX-D or QLX-D 1.X firmware versions. To ensure all receivers and transmitters in a configuration function with each other, update all devices to the same firmware version.

IMPROVEMENTS

  • Compatibility with new products:
    • ULXD6 Wireless Boundary Microphone Transmitter
    • ULXD8 Wireless Gooseneck Base Transmitter
    • SBC450 4-Bay Networked Charging Station 
    • SBC850 8-Bay Networked Charging Station
  • New TPCI commands for charging stations, receivers, and transmitters
  • Bug fixes
    • Custom groups for AB/JB bands now correctly transfer via IR sync
    • Antenna power alert will persist until it is cleared
    • Fixed a sporadic issue of transmitter firmware updates failing

KNOWN ISSUE

  • ULX-D version 2.1.16 is not compatible with SystemOn 2.1

NOTES

  • ULXD1/2 transmitters used with receivers must be updated via IR sync. After a receiver is updated, follow these steps:
    1. Go to the receiver menu: DEVICE UTILITIES > TX FW UPDATE
    2. Align the infrared ports with the transmitter
    3. Press ENTER
  • Maintain an IR connection when updating transmitter firmware via IR sync. In rare occasions, upgrades from 1.5.6 or earlier to 1.6.6 or later can cause transmitters to become non-responsive temporarily. If the update fails and the unit is non-responsive, resolve the issue by following these steps:
    • Using the Shure Update Utility, downgrade the firmware for the ULXD4/ULXD4D/ULXD4Q Receiver to 1.5.6 AND keep the desired transmitter firmware (1.6.6 or later).
    • Update the transmitter firmware to 1.6.6 or later via IR menu. From the receiver menu: DEVICE UTILITIES > TX FW UPDATE. Align the infrared ports with the transmitter and then press ENTER.
    • Upgrade receiver to 1.6.6 or later.
  • To operate ULX-D devices on version 2.1.16 with other Shure networked systems and software, see the following list of minimum software versions: