- Cardioid Polar Pattern
- Picks up the most sound in front of the microphone and some from the sides. Less susceptible to feedback in high volume environments.
- OmniDirectional Polar Pattern
- Equally sensitive to sound from all directions, but cannot be "aimed" to isolate one area.
- SuperCardioid Polar Pattern
- Screens unwanted sound sources. Ideal for individual instruments in a multi-microphone setting, or single sources in noisy environments.
- Tailored Frequency Response
- Smooth, extended response. Tuned to accentuate specific types of instruments, or voices.
MX392 MX393Microflex Boundary Microphones
- Condenser
- Lightweight, sensitive diaphragm. Precisely and smoothly captures sound nuances. Powered by battery or phantom power supply.
- Recommended Uses
- Stage Floor
- Conference/Installed
MX392 and MX393 Microflex® Wired Boundary Microphones from Shure are equipped with features like programmable, silent membrane switches, logic inputs and outputs, and green LED indicators. The high-quality solution for a range of applications such as altars, boardrooms and distance learning centers, Microflex Boundary microphones feature interchangeable condenser cartridges.
- MX392: Surface-mount mic; LED logic input/switch logic output terminals, screw terminal connections, attached unterminated cable
- MX393: Surface-mount mic; miniature three pin connector, 12' XLR cable
- Flat frequency response across the vocal range for uncolored sound
- Interchangeable cardioid, supercardioid, and omnidirectional cartridges that provide optimal choice for each application
- Sleek, low-profile design for unobtrusive appearance
- Balanced, transformerless output for increased immunity to noise over long cable runs
- Programmable membrane on/off switch plus LED on/off indicator
- LED logic input and switch logic output terminals for remote control or use with automatic mixers (MX392 models only)
MX392 & MX 393
- All measurements taken with microphone mounted on a wooden surface 76.2 cm x 76.2 cm (30 in. x 30 in.).
- Frequency Response
- 50 to 17,000 Hz
- Polar Pattern
- Cardioid (MX392/C, MX393/C)
- Supercardioid (MX392/S, MX393/S)
- Omnidirectional (MX392/O, MX393/O)
- Output Impedance
- EIA Rated at 150 ohms (180 ohms actual)
- Sensitivity (at 1 kHz, open circuit voltage)
- Cardioid Cartridge: -27.5 dBV/Pa (42.2 mV)
- Supercardioid Cartridge: -26.5 dBV/Pa (47.3 mV)
- Omnidirectional: -22.0 dBV/Pa (79.4 mV)
- 1 Pascal=94 dB SPL
- Maximum Sound Pressure Level (1 kHz at 1% Total Harmonic Distortion, 1 k ohm load)
- Cardioid: 117.0 dB
- Supercardioid: 116.0 dB
- Omnidirectional: 111.5 dB
- Signal to Noise Ratio (referenced at 94 dB SPL)
- Cardioid: 71.0 dB
- Supercardioid: 72.0 dB
- Omnidirectional: 76.5 dB
- Equivalent Output Noise (A-weighted)
- Cardioid: 23.0 dB SPL
- Supercardioid: 22.0 dB SPL
- Omnidirectional: 17.5 dB SPL
- Dynamic Range
- 94.0 dB
- Common Mode Rejection
- 45 dB minimum, 10 Hz to 100 kHz
- Switch Attenuation
- 50 dB minimum
- Preamplifier Output Clipping Level
- -6 dBV (0.5 V)
- Polarity
- Positive sound pressure on diaphragm produces positive voltage on pin 2 relative to pin 3 of output connector.
- Logic Connections (MX392 Only)
- LED IN: Active low (<1.0v), TTL compatible. Absolute maximum voltage: -0.7V to 50V.
- SWITCH OUT: Active low (<0.5V), sinks up to 20mA, TTL compatible. Absolute maximum voltage: -0.7V to 24V (up to 50V through 3 k ohms).
- Power Requirements
- 11 to 52 Vdc phantom
- 2.0 mA current consumption
- Environmental Requirements
- Operating Temperature Range: -18 to 57 degrees C (0 to 135 degrees F)
- Relative Humidity: 0 to 95%
- Dimensions
- See User Guide
| Name | Availability | |
|---|---|---|
|
R184B and R184W Supercardioid CartridgesSupercardioid cartridge for WL183, WL184, WL185 and all Microflex® MX183, MX202, MX391, MX392, MX393, MX405, MX410, MX415, MX412, and MX418 Microphones. White or Black. |
Where To Buy |
|
R183B and R183W Omnidirectional CartridgeOmnidirectional cartridge for all Microflex® MX183, MX202, MX391, MX392, MX393, MX405, MX410, MX415, MX412, MX418, and WL183 microphones. White or Black. |
Where To Buy |
|
R185B and R185W Cardioid CartridgesCardioid cartridge for all Microflex® MX185, MX202, MX391, MX392, MX393, MX405, MX410, MX415, MX412, MX418, and WL185 microphones. White or Black. |
Where To Buy |
|
RK100PK In-Line PreamplifierIn-Line Preamplifier for Microflex Microphones. Boosts resistance to Radio Frequency Interference (RFI). |
Where To Buy |
|
C129 Cable for Microflex MX393 MicrophoneCable with CommShield® Technology, 3-Pin female mini-connector to male XLR, 12-foot (3.6 m), used with MX393 Microflex microphones. |
Where To Buy |
|
RK183PKW In-Line PreamplifierIn-Line Preamplifier for MX180 Series, MX202B, MX412, MX412SE, and MX391 Microflex Microphones. |
Where To Buy |
|
C119 Cable for Microflex MX393 MicrophoneCable, 3-Pin female mini-connector to male XLR, 12-foot (3.6 m), used with MX393 Microflex microphones. |
Where To Buy |
| User Guides | Language | File Size |
|---|---|---|
| MX392 MX393 User Guide | English, French, German, Italian, Spanish | 14304 (kb) |